Installation

1.Remove any screws or nails from the drywall before beginning.

2.Cut out the surface for the NXD Wall Mount unit using the dimensions shown in FIG. 36. Be sure to cut out the three notches along the sides to accommodate the three corresponding drywall expansion clips (included).

FIG. 36 NXD-CV7 Wall Mount panel dimensions using expansion clips

3.Remove the Faceplate/bezel (A in FIG. 37) from the main NXD unit (B in FIG. 37) by gripping the faceplate and pulling with gentle outward force.

4.Thread the incoming power, RJ-45, Ethernet, USB, and any optional audio/video wiring (from their terminal locations) through the surface opening. Leave enough slack in the wiring to accommodate any re-positioning of the panel.

5.Connect all data and power wiring connectors to their corresponding locations along the left side of the (un-powered) NXD touch panel.

Verify that the terminal end of the power cable is not connected to a power source before plugging in the 2-pin power connector.

The USB connectors can be from a either a USB extension cable, or a wireless USB RF transmitter.

 

36

7" Modero Widescreen Touch Panels

 

 

 

Page 44
Image 44
AMX NXT-CV7 instruction manual NXD-CV7 Wall Mount panel dimensions using expansion clips