Firmware Pages and Descriptions

Calibration Page

This page (FIG. 92) allows you to calibrate the touch panel using the pre-selected touch driver.

Press and hold the grey Front Setup Access button (below the Modero LCD) for 6 seconds to access the Calibration page.

Press the crosshairs to calibrate the panel and return to the last active firmware page.

The request to touch the crosshairs is the first on-screen message

Calibration successful is the second on-screen message that appears after the calibration process is completed

On-screen crosshairs used for calibration of the touch device

FIG. 92 Calibration page (actually 3 separate screens)

If the calibration was improperly set and you cannot return to the Calibration page (through the panel’s firmware); you can access this firmware page via

G4 WebControl where you can navigate to the Protected Setup page and press the Calibrate button through your VNC window.

This action causes the panel to go to the Calibration page seen above, where you can physically recalibrate the actual touch panel again using the above procedures.

Secondary Connection Page

The Secondary Connection page (FIG. 93) sets the communication information for the installed wireless interface card. This information includes its corresponding IP communication parameters, wireless communication settings, and read the device number assigned to the Modero panel. Both CV7 panels can use the NXA-WC80211B/CF wireless card for wireless communication. This card also supports Wired Encryption Protocol (WEP) encryption of 64-bit and 128-bit key lengths. Refer to both the Secondary Connection Page - Wireless Access Overview section on page 55 and Configuring a Wireless Network Access section on page 57 for more detailed information of setting up the Modero panel for wireless network access.

7" Modero Widescreen Touch Panels

105

 

 

 

 

Page 113
Image 113
AMX NXT-CV7, NXD-CV7 instruction manual Calibration, Secondary Connection