CV7 Touch Panel Accessories
15
7" Modero Widescreen Touch Panels
Installation of the Wireless Card (Table Top Panel)
These procedures involve removing the outer housing, installing the wireless card, and then
securely replacing the outer housing back onto the NXT panel.
The CV7 panels do not come factory installed with the NXA-WC802.11B/CF wireless
interface card. This card must be ordered separately from AMX.
Step 1: Removing the NXT Outer Housing
1. Carefully detach all connectors from the rear of the touch panel.
2. Gently place the touch panel LCD facedown onto a soft cloth to expose the under-side of the
base (FIG. 15) and prevent scratching of the LCD. Tilt the base forward so that both the bottom
surface and Housing Screws are easily accessible.
3. While holding the outer housing and base plate at an angle (to prevent it from sliding), use a
grounded Phillips-head screwdriver to remove the four Housing Screws.
Specifications for NXA-WC80211B/CF
Modulation: • DSSS, DBSK, DQSK, CCK
LED Indicators: • Power / Link activity
Antenna: • 2, Ceramic (Diversity Supported)
Receive Sensitivity: @PER < 8%
11 Mbps: -83 dBm (max)
5.5 Mbps: -86 dBm (max)
2 Mbps: -89 dBm (max)
1 Mbps: -92 dBm (max)
Operating Channels: • 11 Channels (USA, Canada)
• 13 Channels (Europe)
• 14 Channels (Japan)
• 4 Channels (France)
Wireless Restrictions: • In R&TTE countries, such as France, the 802.11g frequency band is
restricted to 2454 - 2483.5 MHz (2.4 - 2.4835 GHz) and a max power output
of 100 mW EIRP outdoor.
Operating Environment: • Temperature: 0°C ~ 70°C (non-operating) and -15 ~ 80°C (storage)
• Humidity (non-condensing): 5% ~ 95% RH
Certifications: • FCC (United States)
• IC (Canada)
• CE (Europe)
• TELEC (Japan)
It is recommended that any upgrade of internal equipment be done simultaneously in
order to reduce the risk of damage to internal components.
Do not use Ethernet cables containing mounting boots. These boots could make
removal of the Ethernet connectors (from the panel) difficult and cumbersome.