Configuring Communication
71
7" Modero Widescreen Touch Panels
11. Press the on-screen Reboot button to save any changes and restart the panel.
Master Connection section - NetLinx Master Ethernet IP Address - Auto Mode
In this mode, enter the System Number of the NetLinx Master. This mode instructs the Modero to
search for a Master that uses the same System Number (assigned within the Master Connection
section) and resides on the same Subnet as itself.
1. Toggle the blue Type field until Ethernet is selected (from the Master Connection section of
the System Connection page).
2. Press the Mode field until the choice cycles to the word Auto.
3. Press the System Number field to launch a Keypad and enter the value for the system number of
the NetLinx Master. This value can be obtained from the NetLinx Studio program > OnLine
Tree of the Workspace window.
4. Do not alter the IP Settings section, of the System Connection page, as these fields are not
applicable to this connection mode.
5. Enter a username and password (into their respective fields) if the target Master has been
previously secured.
6. Press the on-screen Reboot button to both save any changes and restart the panel.
7. Press the grey Front Setup Access button for 3 seconds to open the Setup page and confirm
there is an active connection.
Using G4 Web Control to Interact with a G4 Panel
The G4 Web Control feature allows you to use a PC to interact with a G4 enabled panel via the web.
This feature works in tandem with the new browser-capable NetLinx Security firmware update
(build 300 or higher). G4 Web Control is only available with the latest Modero panel firmware.
Refer to the G4 Web Control Pagesection on page 100 for more detailed field information.
1. Press the grey Front Setup Access button for 3 seconds to open the Setup page.
2. Press the Protected Setup button (located on the lower-left of the panel page) to open the
Protected Setup page and display an on-screen keypad.
3. Enter 1988 into the Keypad’s password field (1988 is the default password).
4. Press Done when finished.
5. Press the G4 WebControl button to open the G4 Web Control page (FIG.65).
The NetLinx Master and the Modero panel must both be on the same Subnet.
Verify your NetLinx Master (ME260/64 or NI-Series) has been installed with the latest
firmware KIT file from www.amx.com. Refer to your NetLinx Master instruction
manual for more detailed information on the use of the new web-based NetLinx
Security.
Clearing Password #5, from the initial Password Setup page, removes the need for
you to enter the default password before accessing the Protected Setup page.