Upgrading Modero Firmware

Showing the Virtual Master firmware version and device number

Shows NetLinx Studio version number

Showing the current Modero panel firmware version and device number

FIG. 71 NetLinx Workspace window (showing the panel connection via a Virtual NetLinx Master)

The panel firmware is shown on the right of the listed panel.

Download the latest firmware file from www.amx.com and then save the KIT file to your computer.

5.If the panel firmware version is not the latest available; locate the latest firmware file from the www.amx.com > Tech Center > Downloadable Files > Firmware Files > Modero Panels section of the website.

6.Download the appropriate KIT file to your computer.

7.Verify you have downloaded the latest Modero firmware (KIT) file to a known location.

8.Select Tools > Firmware Transfers > Send to NetLinx Device from the Main menu to open the Send to NetLinx Device dialog (B in FIG. 72). Verify the panel’s System and Device number values match those values listed within the System folder in the OnLine Tree tab of the Workspace window (A in FIG. 72).

A

B

FIG. 72 Using USB for a Virtual Master transfer

9.Select the panel’s KIT file from the Files section.

10.Enter the Device value associated with the panel and the System number associated with the Master (listed in the OnLine Tree tab of the Workspace window). The Port field is greyed-out.

 

80

7" Modero Widescreen Touch Panels

 

 

 

Page 88
Image 88
AMX NXD-CV7, NXT-CV7 instruction manual Select the panel’s KIT file from the Files section