Installation
39
7" Modero Widescreen Touch Panels
4. Thread the incoming power, RJ-45, Ethernet, USB, and any optional audio/video wiring (from
their terminal sources) through the surface opening. Leave enough slack in the wiring to
accommodate any re-positioning of the panel.
5. Connect all data and power wiring connectors to their corresponding locations along the left
side of the (un-powered) NXD touch panel.
Verify that the terminal end of the power cable is not connected to a power source before
plugging in the 2-pin power connector.
The USB connectors can be from a either a USB extension cable, or a wireless USB RF
transmitter.
6. Test the incoming wiring by connecting the panel connections to their terminal locations and
applying power. Verify that the panel is receiving power and functioning properly before
finalizing the installation.
7. Disconnect the terminal end of the power cable from the power supply.
8. Carefully slide the main unit into the cutout until the Mounting Tabs of the CV7 unit lie flush
against the wall.
Don’t disconnect the connectors from the touch panel. The unit must be installed with
the necessary connectors before being inserted into the solid surface.
FIG. 39 Wall Mount panel installation configuration for flat surfaces
B - Main CV7 unit
Install the four #4-40 Mounting Screws
Flat installation surface
A - Faceplate/Trim Ring
Mounting Tab
Attachment is done
along the edges
of the cutout
(included) into these four holes