,'", SEND_COMMAND Panel,"'^GDI-7,128'", "'^GIV-,'", SEND_COMMAND Panel,"'^GIV-500,3'", "'^GLH-,'", SEND_COMMAND Panel,"'^GLH-500,1000'", "'^GLL-,'", SEND_COMMAND Panel,"'^GLL-500,150'" . "'^GDI-,'", SEND_COMMAND Panel,"'^GDI-7,128'", "'^GIV-,'", SEND_COMMAND Panel,"'^GIV-500,3'", "'^GLH-,'""> AMX NXD-CV7, NXT-CV7 "'^GDI-<vt addr range>,<bargraph drag increment>'", SEND_COMMAND Panel,"'^GDI-7,128'", "'^GIV-<vt addr range>,<joystick axis to invert>'", SEND_COMMAND Panel,"'^GIV-500,3'", "'^GLH-<vt addr range>,<bargraph hi>'", SEND_COMMAND Panel,"'^GLH-500,1000'", "'^GLL-<vt addr range>,<bargraph low>'", SEND_COMMAND Panel,"'^GLL-500,150'"
Programming
138 7" Modero Widescreen Touch Panels
The Font ID is generated by TPD4 and is located in TPD4 through the Main menu. Panel > Generate Programmer's Report >Text Only Format >Readme.txt.
"^" Button Commands (Cont.)
^GDI
Change the
bargraph drag
increment.
Syntax:
"'^GDI-<vt addr range>,<bargraph drag increment>'"
Varia ble:
variable text address range = 1 - 4000.
bargraph drag increment = The default drag increment is 256.
Example:
SEND_COMMAND Panel,"'^GDI-7,128'"
Sets the bargraph with variable text 7 to a drag increment of 128.
^GIV
Invert the
joystick axis to
move the origin to
another corner.
Parameters 1,2, and 3 will cause a bargraph or slider to be inverted regardless of
orientation. Their effect will be as described for joysticks.
Syntax:
"'^GIV-<vt addr range>,<joystick axis to invert>'"
Varia ble:
variable text address range = 1 - 4000.
joystick axis to invert = 0 - 3.
For a bargraph 1 = Invert , 0 = Non Invert
Example:
SEND_COMMAND Panel,"'^GIV-500,3'"
Inverts the joystick axis origin to the bottom right corner.
^GLH
Change the
bargraph upper
limit.
Syntax:
"'^GLH-<vt addr range>,<bargraph hi>'"
Varia ble:
variable text address range = 1 - 4000.
bargraph limit range = 1 - 65535 (bargraph upper limit range).
Example:
SEND_COMMAND Panel,"'^GLH-500,1000'"
Changes the bargraph upper limit to 1000.
^GLL
Change the
bargraph lower
limit.
Syntax:
"'^GLL-<vt addr range>,<bargraph low>'"
Varia ble:
variable text address range = 1 - 4000.
bargraph limit range = 1 - 65535 (bargraph lower limit range).
Example:
SEND_COMMAND Panel,"'^GLL-500,150'"
Changes the bargraph lower limit to 150.
0
23
11 = Invert horizontal axis
2 = Invert vertical axis
3 = Invert both axis locations
0 = Normal