Programming

 

"^" Button Commands

 

 

 

 

^ANI

Syntax:

 

Run a button

"'^ANI-<vt addr range>,<start state>,<end state>,<time>'"

 

animation

Variable:

 

(in 1/10 second).

 

variable text address range = 1 - 4000.

 

 

 

 

start state = Beginning of button state (0= current state).

 

 

end state = End of button state.

 

 

time = In 1/10 second intervals.

 

 

Example:

 

 

SEND_COMMAND Panel,"'^ANI-500,1,25,100'"

 

 

Runs a button animation at text range 500 from state 1 to state 25 for 10 second.

 

 

 

 

^APF

Syntax:

 

Add page flip

"'^APF-<vt addr range>,<page flip action>,<page name>'"

 

action to a button

Variable:

 

if it does not

 

variable text address range = 1 - 4000.

 

already exist.

 

 

 

 

page flip action = Stan[dardPage] - Flip to standard page

 

 

Prev[iousPage] - Flip to previous page

 

 

Show[Popup] - Show Popup page

 

 

Hide[Popup] - Hide Popup page

 

 

Togg[lePopup] - Toggle popup state

 

 

ClearG[roup] - Clear popup page group from all pages

 

 

ClearP[age] - Clear all popup pages from a page with the

 

 

specified page name

 

 

ClearA[ll] - Clear all popup pages from all pages

 

 

page name = 1 - 50 ASCII characters.

 

 

Example:

 

 

SEND COMMAND Panel,"'^APF-400,Stan,Main Page'"

 

 

Assigns a button to a standard page flip with page name 'Main Page'.

 

 

 

 

^BAT

Syntax:

 

Append

"'^BAT-<vt addr range>,<button states range>,<new text>'"

 

non-unicode text.

Variable:

 

 

 

 

variable text address range = 1 - 4000.

 

 

button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons

 

 

1 = Off state and 2 = On state).

 

 

new text = 1 - 50 ASCII characters.

 

 

Example:

 

 

SEND_COMMAND Panel,"'^BAT-520,1,Enter City'"

 

 

Appends the text 'Enter City' to the button’s OFF state.

 

 

 

 

^BAU

Same format as ^UNI.

 

Append

Syntax:

 

unicode text.

"'^BAU-<vt addr range>,<button states range>,<unicode

 

 

 

 

text>'"

 

 

Variable:

 

 

variable text address range = 1 - 4000.

 

 

button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons

 

 

1 = Off state and 2 = On state).

 

 

unicode text = 1 - 50 ASCII characters. Unicode characters must be entered in Hex

 

 

format.

 

 

Example:

 

 

SEND_COMMAND Panel,"'^BAU-520,1,00770062'"

 

 

Appends Unicode text '00770062' to the button’s OFF state.

 

 

 

 

7" Modero Widescreen Touch Panels

125

 

 

 

 

Page 133
Image 133
AMX NXT-CV7, NXD-CV7 instruction manual Button Commands