Configuring Communication

DHCP will register the unique MAC Address (factory assigned) on the panel and once the communication setup process is complete, reserve an IP Address, Subnet Mask, and Gateway values from the DHCP Server.

4.Press the optional Host Name field to open a Keyboard and enter the Host Name information.

5.Press Done after you are finished assigning the alpha-numeric string of the host name.

6.Do not alter any of the remaining greyed-out fields in the IP Settings section. Once the panel is rebooted, these values are obtained by the unit and displayed in the DNS fields after power-up.

This information can be found in either the: Workspace- System name > Define Device section of your code (that defines the properties for your panel), or in the Device Addressing/Network Addresses in the Tools > NetLinx Diagnostics dialog.

7.Press the Back button to return to the Protected Setup page.

8.Press the on-screen Reboot button to both save any changes and restart the panel.

IP Settings section - Configuring a Static IP Address over Ethernet

1.Select Protected Setup > System Connection (located on the lower-left) to open the System Connection page.

2.Locate the IP Settings section of this page.

Check with your System Administrator for a pre-reserved Static IP Address assigned to the panel. This address must be obtained before Static assignment of the panel continues.

3.Toggle the DHCP/Static field (from the IP Settings section) until the choice cycles to Static.

4.Press the IP Address field to open a Keyboard and enter the Static IP Address (provided by your System Administrator).

5.Press Done after you are finished entering the IP information.

6.Repeat the same process for the Subnet Mask and Gateway fields.

7.Press the optional Host Name field to open the Keyboard and enter the Host Name information.

8.Press Done after you are finished assigning the alpha-numeric string of the host name.

9.Press the Primary DNS field to open a Keyboard, enter the Primary DNS Address (provided by your System Administrator) and press Done when compete. Repeat this process for the Secondary DNS field.

10.Press the Domain field to open a Keyboard, enter the resolvable domain Address (this is provided by your System Administrator and equates to a unique Internet name for the panel), and press Done when complete.

11.Navigate to the Master Connection section of this page to begin configuring the communication parameters for the target Master.