Troubleshooting

The treadmill is designed and manufactured to be reliable and easy to use. However, if

Problem:

The console is erratic or not lighting up

Solution:

Check to make sure that the treadmill is properly plugged in, turn the power

 

Check all wire harness connections to be sure they are all properly connected.

 

If the problem persists contact LifeSpan Customer Service.

Problem:

The belt does not stay in the center of the treadmill when in use.

Solution:

First check to make sure that the treadmill is level, then refer to the instructions in

 

this manual on how to tension and adjust the belt.

Problem:

The treadmill motor seems strained or E1 comes up after several minutes of use.

Solution:

The lubricating silicone that is applied to the deck and belt is wearing down and

 

the belt needs to be lubricated with silicone spray.

Problem:

The treadmill belt slips during use.

Solution:

The belt may need to be tensioned after a period of use. Refer to the Belt

 

Tensioning and Adjustment Section of this manual.

Problem:

Speed does not match quick keys. Treadmill Starts at 1 and goes to 16.

Solution:

The treadmill is set up in Metric Mode. See chart on next page for Console

 

Engineering Mode.

Problem:

Heart Rate is erratic or not picking up.

Solution:

Make sure your hands are moist (Aloe Vera helps). Make sure all connectors at the

 

back of the console are properly connected and no wires are damaged.

 

If wearing a chest strap make sure the batteries are good and that the electrodes

 

are moist and positioned properly on your chest.

Problem:

Treadmill automaticaly pauses during workout.

Solution:

Treadmill is not picking up Step Count. Go into Engineering Mode to turn intelli-

 

Warning: This will disengage the intelli-guard feature but may be necessary

Problem:

Silicone icon lights up on console.

Solution:

Lubricate the running belt with 100% pure silicone. Then simultaneously press

34

Page 34
Image 34
LifeSpan TR1200I manual Troubleshooting