temperature display.

TROUBLESHOOTING GUIDE

ELECTRIC OVENS

MODEL 1164-000-EA

400/230 VAC

50 HZ.

3 PHASE

REFER TO PROPER SCHEMATIC FOR IDENTIFIED COMPONENTS

 

 

 

 

SYMPTOM

POSSIBLE CAUSE

EVALUATION

 

Oven fan will not run

Incoming power supply

Check circuit breakers. Reset if required. Call

 

 

 

power company if needed.

 

Oven cavity hi-limit

Terminals are normally closed. If open, reset

 

thermostat

 

and test oven for proper operation. If

 

 

 

thermostat will not hold for maximum oven

 

 

 

temperature, and oven is not exceeding

 

 

 

temperature dial setting, check for proper

 

 

 

location of capillary bulb in its spring holder. If

 

 

 

above checks okay, replace hi-limit thermostat.

 

Fuse, 10 Amp

 

Check, replace if necessary.

 

Fuse holder

 

Check, replace if necessary.

 

Control box hi-limit thermostat

Check for voltage on both sides of the switch.

 

 

 

Terminals are normally closed. If open, reset

 

 

 

and test oven for proper operation. If

 

 

 

thermostat will not hold, and control box

 

 

 

temperature is not exceeding 140° F (60° C)

 

 

 

replace thermostat.

 

 

Main fan switch

With power off, Check continuity between

 

 

 

switch terminals. Replace as needed.

 

Main fan motor

 

Check for opens, shorts or grounds. With

 

 

 

power off, turn fan blade to check for locked

 

 

 

rotor.

 

 

Capacitor

 

Check for shorts or grounds.

 

 

 

WARNING: Capacitor has a stored charge,

 

 

 

discharge before testing.

No control box cooling

 

 

Check for main fan operation. If not operating,

 

 

 

refer to “Oven fan will not run”.

 

Cooling fan

 

Line voltage should now be at the cooling fan.

 

 

 

If voltage is present, check motor for shorts or

 

 

 

opens. With power off, check for locked rotor.

No automatic control box

Incoming power supply

Check circuit breakers. Reset if required. Call

cooling

 

 

power company if needed.

 

Oven cavity hi-limit

Terminals are normally closed. If open, reset

 

thermostat

 

and test oven for proper operation. If

 

 

 

thermostat will not hold for maximum oven

 

 

 

temperature, and oven is not exceeding

 

 

 

temperature dial setting, check for proper

 

 

 

location of capillary bulb in its spring holder. If

 

 

 

above checks okay, replace hi-limit thermostat.

 

Cooling fan thermostat

Check the cooling fan thermostat (thermostat

 

 

 

closes at 120° F and opens at 100° F). With the

 

 

 

cooling fan thermostat preheated, check for

 

 

 

continuity. If switch is open, replace thermostat.

 

Cooling fan

 

Line voltage should now be at the cooling fan.

 

 

 

If voltage is present, check motor for shorts or

 

 

 

opens. With power off, check for locked rotor.

Control box cooling fan

Cooling fan thermostat

This normally open thermostat should close at

continues to run

 

 

120°F (48.9°C) and reopen at 100°F (37.8°C).

 

 

 

Replace as needed.

 

Impinger II – 1100-000-A Series (SN 2038615 & Below) Service Manual –Int’l

11

Page 11
Image 11
Lincoln 1100-000-A SERIES (SN 2038615 & BELOW) service manual Troubleshooting Guide Electric Ovens