BYPASS ORIFICE – REPLACEMENT

 

.

Shut off power at main breaker.

 

.

Shut off gas supply to oven.

 

.

Remove control panel top and front cover.

 

.

Remove pilot tube from bypass orifice and remove orifice.

 

.

Reassemble in reverse order and check system operation.

 

.

Check gas line fittings for leaks.

 

TEMPERATURE REGULATION VALVE – REPLACEMENT

 

.

Shut off power at main breaker.

 

.

Shut off gas supply to oven.

 

.

Remove control panel top and front cover.

 

.

Remove bypass tube from burner.

 

.

Disconnect wires from temperature regulation valve and mark for reassembly.

 

.

Remove four nuts from burner manifold and disconnect pipe union.

 

.

Remove temperature regulation valve and piping from oven.

 

.

Remove piping from valve and reassemble in reverse order and check system operation. Check all gas line

 

 

fittings for leaks.

 

IGNITER/SENSOR ASSEMBLY – REPLACEMENT

 

.

Shut off power at main breaker.

 

.

Shut off gas supply to oven.

 

.

Remove control panel top and front cover.

 

. Remove gas valve assembly.(see “GAS VALVE”)

 

.

Remove temperature regulation valve. (see “TEMPERATURE REGULATION VALVE”)

 

.

Disconnect all wires from burner and mark for reassembly.

 

.

Remove screws from burner tube and remove burner venturi.

 

.

Remove two mounting screws and remove igniter/sensor assembly from burner venturi.

 

.

Reassemble in reverse order and check system operation. Check all gas line fittings for leaks.

 

Impinger II – 1100-000-A Series (SN 2038615 & Below) Service Manual –Int’l

19

Page 19
Image 19
Lincoln 1100-000-A SERIES (SN 2038615 & BELOW) Bypass Orifice Replacement, Temperature Regulation Valve Replacement