Lincoln 116-000-A, 1133-000-A, 1131-000-A, 1130-000-A, 1132-000-A Troubleshooting Guide Gas Ovens

Models: 1117-000-A 1132-000-A 1130-000-A 1131-000-A 116-000-A 1133-000-A

1 32
Download 32 pages 25.41 Kb
Page 7
Image 7

TROUBLESHOOTING GUIDE

GAS OVENS

SERIAL NUMBER 2038616 AND ABOVE (OVENS WITH PUSH BUTTON CONTROLS)

MODEL 1116-000-A

NAT. GAS

120VAC

60 HZ.

MODEL 1117-000-A

LP GAS

120VAC

60 HZ.

 

 

 

 

 

 

SYMPTOM

POSSIBLE CAUSE

 

 

EVALUATION

 

 

 

 

 

Oven fan will not run

Incoming power supply

 

Check circuit breakers, reset if required. Check

 

 

 

 

power plug to be sure it is firmly in receptacle.

 

 

 

 

Measure incoming power, call power co. if

 

 

 

 

needed.

 

 

Fuse, 10 Amp

 

 

Check, replace if necessary.

 

Fuse holder

 

 

Check, replace if necessary.

 

Hi-limit thermostat,

 

 

Check for voltage on both sides of switch.

 

control box

 

 

Terminals are normally closed. If open, reset and

 

 

 

 

test oven for proper operation. If thermostat will

 

 

 

 

not hold, and control box temperature is not

 

 

 

 

exceeding 140°F (60°C), replace thermostat.

 

Switch, main power

 

 

Check continuity between switch terminals.

 

 

 

 

Replace switch as needed.

 

Main fan motor

 

 

Check for 120VAC at motor. If no voltage is

 

 

 

 

present, trace wiring back to main power switch.

 

 

 

 

WITH POWER OFF: Check for opens, shorts or

 

 

 

 

grounds. Turn fan blade to check for locked rotor.

 

Capacitor

 

 

Check for shorts or grounds.

 

 

 

 

WARNING: Capacitor has a stored charge,

 

 

 

 

discharge before testing.

No control box cooling

Incoming power

 

 

Check circuit breakers, reset if required. Check

 

 

 

 

power plug to be sure it is firmly in receptacle.

 

 

 

 

Measure incoming power, call power co. if

 

 

 

 

needed.

 

 

Switch, main power

 

 

Check continuity between switch terminals.

 

 

 

 

Replace switch as needed.

 

Cooling fan

 

 

Check for 120VAC at cooling fan. If no voltage is

 

 

 

 

present, trace wiring back to power switch. If

 

 

 

 

voltage is present, and motor does not run, check

 

 

 

 

for opens, shorts or grounds.

 

 

 

 

WITH POWER OFF: Check for locked rotor.

No automatic control box

Incoming power supply

 

Check circuit breakers, reset if required. Check

cooling

 

 

 

power plug to be sure it is firmly in receptacle.

 

 

 

 

Measure incoming power, call power co. if

 

 

 

 

needed.

 

 

Cooling fan thermostat

 

Check the cooling fan thermostat. (Thermostat

 

 

 

 

closes at 120°F and opens at 100°F). With the

 

 

 

 

cooling fan thermostat pre-heated, check for

 

 

 

 

continuity. If switch is open, replace cooling fan

 

 

 

 

thermostat.

 

 

Cooling fan

 

 

Check for 120VAC at cooling fan. If no voltage is

 

 

 

 

present, trace wiring back to cooling fan

 

 

 

 

thermostat. If voltage is present, and motor does

 

 

 

 

not run, check for opens, shorts or grounds.

 

 

 

 

WITH POWER OFF: Check for locked rotor.

Oven will not heat

Gas supply

 

 

Check for adequate gas supply to oven.

 

Manual gas shut off valve.

 

Check to see that the manual gas shut off valve is

 

 

 

 

open. Also check flexible gas line connection for

 

 

 

 

any damage.

 

Impinger II – Advantage Digital Service Manual - Domestic

7

Page 7
Image 7
Lincoln 116-000-A, 1133-000-A, 1131-000-A, 1130-000-A, 1132-000-A, 1117-000-A service manual Troubleshooting Guide Gas Ovens