Lincoln 1132-000-A out on the control. If the control reads “PROBE, Thermocouple, Oven control

Models: 1117-000-A 1132-000-A 1130-000-A 1131-000-A 116-000-A 1133-000-A

1 32
Download 32 pages 25.41 Kb
Page 10
Image 10

 

 

voltage output at the oven control, check the read-

 

 

out on the control. If the control reads “PROBE

 

 

FAIL”, this indicates that the thermocouple has

 

 

failed or become disconnected from the oven

 

 

control.

 

Thermocouple

Check to be sure that the thermocouple is

 

 

securely connected to the oven control. If the

 

 

thermocouple is connected to the oven control,

 

 

and the control indicates “PROBE FAIL”,

 

 

disconnect the thermocouple from the oven

 

 

control and measure the resistance of the

 

 

thermocouple. The thermocouple should read

 

 

approx. 11Ω. If these readings are not achieved,

 

 

replace the thermocouple. If these readings are

 

 

correct, proceed.

 

Oven control

If the thermocouple checks good, but the oven

 

 

control display indicates that there is a

 

 

thermocouple failure, replace the oven control. If

 

 

the oven control indicates a temperature reading

 

 

but the oven will not heat, proceed.

 

Thermocouple

WITH POWER ON AND THERMOCOUPLE

 

 

ATTACHED TO THE OVEN CONTROL: Measure

 

 

the DC millivolt output of the thermocouple. Refer

 

 

to the thermocouple chart (located in the

 

 

“Removal” section of the manual) for proper

 

 

millivolt readings. If these readings are not

 

 

achieved, replace thermocouple.

 

Oven control

If the thermocouple checks good, but there is no

 

 

120VAC output to the temperature regulation

 

 

valve, replace the oven control. If there is 120VAC

 

 

output to the temperature regulation valve,

 

 

proceed.

 

Temperature regulation valve

Check for 120VAC supplied to temperature

 

 

regulation valve. If voltage is present, listen for

 

 

valve to open and close. Also check for opens or

 

 

shorts in the operating coil. Replace temperature

 

 

regulation valve as needed.

Intermittent heating

Thermal/overload of main fan

The main fan motor and burner blower motor are

 

and burner blower motors

equipped with internal thermal protection and will

 

 

cease to operate if overheating occurs. As the

 

 

motors overheat and then cool, this will cause the

 

 

heating system to cycle on and off intermittently.

 

 

Improper ventilation or lack of preventive

 

 

maintenance may cause this problem. Also, most

 

 

of the problems listed under “Oven will not heat”

 

 

can cause intermittent failure.

Conveyor will not run

Power supply

Check for incoming voltage at line 1 to neutral.

 

 

There should be a reading of 120VAC. If not

 

 

present, check circuit breakers.

 

Fuse, 10 Amp

Check, replace if necessary.

 

Fuse holder

Check, replace if necessary.

 

Hi-limit thermostat, control box

Check for voltage on both sides of switch.

 

 

Terminals are normally closed. If open, reset and

 

 

test oven for proper operation. If thermostat will

 

 

not hold, and control box temperature is not

 

 

exceeding 140°F (60°C), replace thermostat.

 

Power switch

Check continuity between switch terminals.

 

 

Replace switch as needed.

 

Control transformer

Check for 120 VAC supply to the primary of the

 

 

control transformer. If no voltage is present, trace

10

Impinger II – Advantage Digital Service Manual - Domestic

Page 10
Image 10
Lincoln 1132-000-A out on the control. If the control reads “PROBE, FAIL”, this indicates that the thermocouple has