United States of America Phone : 800
Lincoln Foodservice Products, LLC
1111 North Hadley Road Fort Wayne, Indiana
U.S. Fax: 888 790-8193• Int’l Fax: 260
SEQUENCE OF OPERATION IMPINGER II ADVANTAGE
SEQUENCE OF OPERATION IMPINGER II ADVANTAGE
1130-000-A
SCHEMATIC DIAGRAM
SCHEMATIC DIAGRAM MODEL 1130-000-A, 1131-000-A
SERIAL NUMBER 2038616 AND ABOVE
SCHEMATIC DIAGRAM MODEL 1132-000-A, 1133-000-A
SERIAL NUMBER 2038616 AND ABOVE
TROUBLESHOOTING GUIDE GAS OVENS
switch, located at 6-pinconnector in raceway near
Centrifugal switch of main fan
Check for 120VAC at wire #5 input to centrifugal
present, trace wiring back to the main power
the temperature control to the lowest setting
control will shut off and lock out. To reset the
ignition control, turn off the power switch for
Power supply
to the thermocouple chart located in the
the oven control indicates a temperature reading
WITH POWER ON AND THERMOCOUPLE
120VAC output to the temperature regulation
WITH POWER OFF: Check the motor windings as
at wire #14 to neutral. If no voltage is present
trace wiring back to the primary of the control
discharge before testing
TROUBLESHOOTING GUIDE ELECTRIC OVENS
is present, trace wiring back to control
for maximum oven temperature, and oven is not
exceeding temperature setting, check for proper
control to maximum temperature see installation
WITH POWER OFF: To check resistance of the
Check the Amp draw on each power leg for
proper load. Check the specification plate for
Oven heats with switch off
Check continuity between switch terminals
discharge before testing
Switch, conveyor reversing
Replace switch as needed
REMOVAL, INSTALLATION AND ADJUSTMENTS
IMPINGER II ADVANTAGE SERIES
THERMOSTAT, CONTROL BOX HI-LIMIT– REPLACEMENT
FUSE HOLDER – REPLACEMENT
A.Shut off power at main breaker
A.Shut off power at main breaker
TRANSFORMER, BURNER – REPLACEMENT
See “TRANSFORMER –BURNER- REPLACEMENT
GAS VALVE – REPLACEMENT
BURNER CONTROL – REPLACEMENT
A.Shut off power at main breaker
A.Shut off power at main breaker
MAIN BURNER ORIFICE – REPLACEMENT
BYPASS ORIFICE – REPLACEMENT
A.Shut off power at main breaker
A.Shut off power at main breaker
D.Disconnect air tube from air pressure switch
AIR PRESSURE SWITCH – REPLACEMENT
A.Shut off power at main breaker
BEARING, CONVEYOR – REPLACEMENT
IMPINGER II ADVANTAGE
GENERAL VIEW
Page
CONTROL BOX MODEL 1116-000-A, 1117-000-A
Page
OVENS WITH PUSH BUTTON CONTROLS
CONTROL BOX
SERIAL NUMBER 2038616 AND ABOVE
Page
OVEN BACK ASSEMBLY
Page
CONVEYOR / DOOR