Lincoln 1133-000-A Transformer, Burner – Replacement, See “TRANSFORMER –BURNER- REPLACEMENT

Models: 1117-000-A 1132-000-A 1130-000-A 1131-000-A 116-000-A 1133-000-A

1 32
Download 32 pages 25.41 Kb
Page 18
Image 18

TRANSFORMER, BURNER – REPLACEMENT

A.Shut off power at main breaker.

B.Remove control panel top and front cover.

C.Remove all wires from transformer and mark for reassembly.

D.Remove two mounting screws from transformer base and remove transformer.

E.Reassemble in reverse order and check system operation.

OVEN CONTROL – REPLACEMENT

A.Shut off power at main breaker.

B.Remove control box cover and front panel.

C.Remove all wiring connections and mark for reassembly.

D.Remove oven control by pulling control from the mounting pins. Remove control from oven.

E.Before installing new oven control, set voltage jumper (located at the bottom center of the oven control) to the proper voltage (120V/240V) position. Install the four pushbutton extensions (included with the oven control) by pushing the extensions onto the four set buttons on control.

F.Reassemble in reverse order and check system operation.

G.Set the oven control for the proper operating mode. The 1100 series ovens use a single temperature control system. The oven control must be set to the proper operating mode. Set the control as follows: With the oven power switch “off”, depress the “time” and “up” buttons and turn the oven “on”. Control will indicate ”Imp I or Imp II” Release the buttons, The control will indicate “Temp to store”. Press the “up” or “down” button until “Imp II” appears on the display. Press the “temp” button. The control is now set for single burner operation.

TRANSFORMER – CONTROL – REPLACEMENT

See “TRANSFORMER –BURNER - REPLACEMENT

THERMOCOUPLE – REPLACEMENT

A.Shut off power at main breaker.

B.Remove conveyor and bottom finger assembly.

C.Remove control panel top and front cover.

D.Remove thermocouple from bracket in oven chamber and pull thermocouple through tube into control box.

E.Remove two thermocouple wires from temperature control. Note wire color and location for reassembly

F.Reassemble in reverse order and check system operation

THERMOCOUPLE MEASUREMENT

TEMPERATURE (°F)

D.C. MILLIVOLTS

200°

2.8

250°

4.0

300°

5.1

350°

6.0

400°

7.1

450°

8.2

500°

9.3

550°

10.4

600°

11.5

18

Impinger II – Advantage Digital Service Manual - Domestic

Page 18
Image 18
Lincoln 1133-000-A, 116-000-A, 1131-000-A Transformer, Burner – Replacement, See “TRANSFORMER –BURNER- REPLACEMENT