489

 

 

 

 

Modbus Memory Map

 

Communications Guide

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 1: 489 Memory Map (Sheet 22 of 29)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ADDR

NAME

RANGE

STEP

UNITS

FORMAT

DEFAULT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

26A4

RTD #11 Alarm Events

0 to 1

1

F105

0

 

 

 

 

 

 

 

 

 

 

 

26A5

RTD #11 Trip

0 to 2

1

F115

0

 

 

 

 

 

 

 

 

 

 

 

26A6

RTD #11 Trip Voting

1 to 12

1

F122

11

 

 

 

 

 

 

 

 

 

 

 

26A7

Assign Trip Relays (1-4)

0 to 3

1

F50

1

 

 

 

 

 

 

 

 

 

 

 

26A8

RTD #11 Trip Temperature

1 to 250

1

°C

F1

90

 

 

 

 

 

 

 

 

 

 

 

26A9

RTD #11 Name

0 to 8

1

F22

_

 

 

 

 

 

 

 

 

 

 

 

RTD TEMPERATURE / RTD #12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

26E0

RTD #12 Application

0 to 4

1

F121

3

 

 

 

 

 

 

 

 

 

 

 

26E1

RTD #12 Alarm

0 to 2

1

F115

0

 

 

 

 

 

 

 

 

 

 

 

26E2

Assign Alarm Relays (2-5)

1 to 4

1

F50

16

 

 

 

 

 

 

 

 

 

 

 

26E3

RTD #12 Alarm Temperature

1 to 250

1

°C

F1

60

 

 

 

 

 

 

 

 

 

 

 

26E4

RTD #12 Alarm Events

0 to 1

1

F105

0

 

 

 

 

 

 

 

 

 

 

 

26E5

RTD #12 Trip

0 to 2

1

F115

0

 

 

 

 

 

 

 

 

 

 

 

26E6

RTD #12 Trip Voting

1 to 12

1

F122

12

 

 

 

 

 

 

 

 

 

 

 

26E7

Assign Trip Relays (1-4)

0 to 3

1

F50

1

 

 

 

 

 

 

 

 

 

 

 

26E8

RTD #12 Trip Temperature

1 to 250

1

°C

F1

80

 

 

 

 

 

 

 

 

 

 

 

26E9

RTD #12 Name

0 to 8

1

F22

_

 

 

 

 

 

 

 

 

 

 

 

RTD TEMPERATURE / OPEN RTD SENSOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2720

Open RTD Sensor Alarm

0 to 2

1

F115

0

 

 

 

 

 

 

 

 

 

 

 

2721

Assign Alarm Relays (2-5)

1 to 4

1

F50

16

 

 

 

 

 

 

 

 

 

 

 

2722

Open RTD Sensor Alarm Events

0 to 1

1

F105

0

 

 

 

 

 

 

 

 

 

 

 

RTD TEMPERATURE / RTD SHORT/LOW TEMPERATURE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2740

RTD Short/Low Temperature Alarm

0 to 2

1

F115

0

 

 

 

 

 

 

 

 

 

 

 

2741

Assign Alarm Relays (2-5)

1 to 4

1

F50

16

 

 

 

 

 

 

 

 

 

 

 

2742

RTD Short/Low Temperature Alarm Events

0 to 1

1

F105

0

 

 

 

 

 

 

 

 

 

 

 

THERMAL MODEL / MODEL SETUP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2800

Enable Thermal Model

0 to 1

1

F103

0

 

 

 

 

 

 

 

 

 

 

 

2801

Overload Pickup Level

101 to 125

1

FLA

F3

101

 

 

 

 

 

 

 

 

 

 

 

2802

Unbalance Bias K Factor

0 to 12

1

F1

0

 

 

 

 

 

 

 

 

 

 

 

2803

Cool Time Constant Online

0 to 500

1

min

F1

15

 

 

 

 

 

 

 

 

 

 

 

2804

Cool Time Constant Offline

0 to 500

1

min

F1

30

 

 

 

 

 

 

 

 

 

 

 

2805

Hot/Cold Safe Stall Ratio

1 to 100

1

F3

100

 

 

 

 

 

 

 

 

 

 

 

2806

Enable RTD Biasing

0 to 1

1

F103

0

 

 

 

 

 

 

 

 

 

 

 

2807

RTD Bias Minimum

0 to 250

1

°C

F1

40

 

 

 

 

 

 

 

 

 

 

 

2808

RTD Bias Center Point

0 to 250

1

°C

F1

130

 

 

 

 

 

 

 

 

 

 

 

2809

RTD Bias Maximum

0 to 250

1

°C

F1

155

 

 

 

 

 

 

 

 

 

 

 

280A

Select Curve Style

0 to 2

1

F142

0

 

 

 

 

 

 

 

 

 

 

 

280B

Standard Overload Curve Number

1 to 15

1

F1

4

 

 

 

 

 

 

 

 

 

 

 

280C

Time to Trip at 1.01 FLA

5 to 999999

1

s

F10

5

 

 

 

 

 

 

 

 

 

 

 

280E

Time to Trip at 1.05 FLA

5 to 999999

1

s

F10

5

 

 

 

 

 

 

 

 

 

 

 

2810

Time to Trip at 1.10 FLA

5 to 999999

1

s

F10

5

 

 

 

 

 

 

 

 

 

 

 

2812

Time to Trip at 1.20 FLA

5 to 999999

1

s

F10

5

 

 

 

 

 

 

 

 

 

 

 

2814

Time to Trip at 1.30 FLA

5 to 999999

1

s

F10

5

 

 

 

 

 

 

 

 

 

 

 

2816

Time to Trip at 1.40 FLA

5 to 999999

1

s

F10

5

 

 

 

 

 

 

 

 

 

 

 

2818

Time to Trip at 1.50 FLA

5 to 999999

1

s

F10

5

 

 

 

 

 

 

 

 

 

 

 

281A

Time to Trip at 1.75 FLA

5 to 999999

1

s

F10

5

 

 

 

 

 

 

 

 

 

 

 

281C

Time to Trip at 2.00 FLA

5 to 999999

1

s

F10

5

 

 

 

 

 

 

 

 

 

 

 

281E

Time to Trip at 2.25 FLA

5 to 999999

1

s

F10

5

 

 

 

 

 

 

 

 

 

 

 

2820

Time to Trip at 2.50 FLA

5 to 999999

1

s

F10

5

 

 

 

 

 

 

 

 

 

 

 

2822

Time to Trip at 2.75 FLA

5 to 999999

1

s

F10

5

 

 

 

 

 

 

 

 

 

 

 

2824

Time to Trip at 3.00 FLA

5 to 999999

1

s

F10

5

 

 

 

 

 

 

 

 

 

 

 

2826

Time to Trip at 3.25 FLA

5 to 999999

1

s

F10

5

 

 

 

 

 

 

 

 

 

 

 

2828

Time to Trip at 3.50 FLA

5 to 999999

1

s

F10

5

 

 

 

 

 

 

 

 

 

 

 

1, 2, 3 See Table footnotes on page 39

32

http://www.GEindustrial.com/multilin

GE Multilin

Page 36
Image 36
GE 1601-0149-A2 manual Memory Map Sheet 22, RTD Temperature / RTD #12, RTD Temperature / Open RTD Sensor