489

 

 

 

 

Modbus Memory Map

 

Communications Guide

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 1: 489 Memory Map (Sheet 20 of 29)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ADDR

NAME

RANGE

STEP

UNITS

FORMAT

DEFAULT

 

 

 

 

 

 

 

 

 

 

2428

RTD #1 Trip Temperature

1 to 250

1

°C

F1

155

 

 

 

 

 

 

 

 

 

 

 

2429

RTD #1 Name

0 to 8

1

F22

_

 

 

 

 

 

 

 

 

 

 

 

RTD TEMPERATURE / RTD #2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2460

RTD #2 Application

0 to 4

1

F121

1

 

 

 

 

 

 

 

 

 

 

 

2461

RTD #2 Alarm

0 to 2

1

F115

0

 

 

 

 

 

 

 

 

 

 

 

2462

Assign Alarm Relays (2-5)

1 to 4

1

F50

16

 

 

 

 

 

 

 

 

 

 

 

2463

RTD #2 Alarm Temperature

1 to 250

1

°C

F1

130

 

 

 

 

 

 

 

 

 

 

 

2464

RTD #2 Alarm Events

0 to 1

1

F105

0

 

 

 

 

 

 

 

 

 

 

 

2465

RTD #2 Trip

0 to 2

1

F115

0

 

 

 

 

 

 

 

 

 

 

 

2466

RTD #2 Trip Voting

1 to 12

1

F122

2

 

 

 

 

 

 

 

 

 

 

 

2467

Assign Trip Relays (1-4)

0 to 3

1

F50

1

 

 

 

 

 

 

 

 

 

 

 

2468

RTD #2 Trip Temperature

1 to 250

1

°C

F1

155

 

 

 

 

 

 

 

 

 

 

 

2469

RTD #2 Name

0 to 8

1

F22

_

 

 

 

 

 

 

 

 

 

 

 

RTD TEMPERATURE / RTD #3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24A0

RTD #3 Application

0 to 4

1

F121

1

 

 

 

 

 

 

 

 

 

 

 

24A1

RTD #3 Alarm

0 to 2

1

F115

0

 

 

 

 

 

 

 

 

 

 

 

24A2

Assign Alarm Relays (2-5)

1 to 4

1

F50

16

 

 

 

 

 

 

 

 

 

 

 

24A3

RTD #3 Alarm Temperature

1 to 250

1

°C

F1

130

 

 

 

 

 

 

 

 

 

 

 

24A4

RTD #3 Alarm Events

0 to 1

1

F105

0

 

 

 

 

 

 

 

 

 

 

 

24A5

RTD #3 Trip

0 to 2

1

F115

0

 

 

 

 

 

 

 

 

 

 

 

24A6

RTD #3 Trip Voting

1 to 12

1

F122

3

 

 

 

 

 

 

 

 

 

 

 

24A7

Assign Trip Relays (1-4)

0 to 3

1

F50

1

 

 

 

 

 

 

 

 

 

 

 

24A8

RTD #3 Trip Temperature

1 to 250

1

°C

F1

155

 

 

 

 

 

 

 

 

 

 

 

24A9

RTD #3 Name

0 to 8

1

F22

_

 

 

 

 

 

 

 

 

 

 

 

RTD TEMPERATURE / RTD #4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24E0

RTD #4 Application

0 to 4

1

F121

1

 

 

 

 

 

 

 

 

 

 

 

24E1

RTD #4 Alarm

0 to 2

1

F115

0

 

 

 

 

 

 

 

 

 

 

 

24E2

Assign Alarm Relays (2-5)

1 to 4

1

F50

16

 

 

 

 

 

 

 

 

 

 

 

24E3

RTD #4 Alarm Temperature

1 to 250

1

°C

F1

130

 

 

 

 

 

 

 

 

 

 

 

24E4

RTD #4 Alarm Events

0 to 1

1

F105

0

 

 

 

 

 

 

 

 

 

 

 

24E5

RTD #4 Trip

0 to 2

1

F115

0

 

 

 

 

 

 

 

 

 

 

 

24E6

RTD #4 Trip Voting

1 to 12

1

F122

4

 

 

 

 

 

 

 

 

 

 

 

24E7

Assign Trip Relays (1-4)

0 to 3

1

F50

1

 

 

 

 

 

 

 

 

 

 

 

24E8

RTD #4 Trip Temperature

1 to 250

1

°C

F1

155

 

 

 

 

 

 

 

 

 

 

 

24E9

RTD #4 Name

0 to 8

1

F22

_

 

 

 

 

 

 

 

 

 

 

 

RTD TEMPERATURE / RTD #5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2520

RTD #5 Application

0 to 4

1

F121

1

 

 

 

 

 

 

 

 

 

 

 

2521

RTD #5 Alarm

0 to 2

1

F115

0

 

 

 

 

 

 

 

 

 

 

 

2522

Assign Alarm Relays (2-5)

1 to 4

1

F50

16

 

 

 

 

 

 

 

 

 

 

 

2523

RTD #5 Alarm Temperature

1 to 250

1

°C

F1

130

 

 

 

 

 

 

 

 

 

 

 

2524

RTD #5 Alarm Events

0 to 1

1

F105

0

 

 

 

 

 

 

 

 

 

 

 

2525

RTD #5 Trip

0 to 2

1

F115

0

 

 

 

 

 

 

 

 

 

 

 

2526

RTD #5 Trip Voting

1 to 12

1

F122

5

 

 

 

 

 

 

 

 

 

 

 

2527

Assign Trip Relays (1-4)

0 to 3

1

F50

1

 

 

 

 

 

 

 

 

 

 

 

2528

RTD #5 Trip Temperature

1 to 250

1

°C

F1

155

 

 

 

 

 

 

 

 

 

 

 

2529

RTD #5 Name

0 to 8

1

F22

_

 

 

 

 

 

 

 

 

 

 

 

RTD TEMPERATURE / RTD #6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2560

RTD #6 Application

0 to 4

1

F121

1

 

 

 

 

 

 

 

 

 

 

 

2561

RTD #6 Alarm

0 to 2

1

F115

0

 

 

 

 

 

 

 

 

 

 

 

2562

Assign Alarm Relays (2-5)

1 to 4

1

F50

16

 

 

 

 

 

 

 

 

 

 

 

2563

RTD #6 Alarm Temperature

1 to 250

1

°C

F1

130

 

 

 

 

 

 

 

 

 

 

 

2564

RTD #6 Alarm Events

0 to 1

1

F105

0

 

 

 

 

 

 

 

 

 

 

 

2565

RTD #6 Trip

0 to 2

1

F115

0

 

 

 

 

 

 

 

 

 

 

 

1, 2, 3 See Table footnotes on page 39

30

http://www.GEindustrial.com/multilin

GE Multilin

Page 34
Image 34
GE 1601-0149-A2 manual Memory Map Sheet 20