Modbus Memory Map
Table 1: 489 Memory Map (Sheet 27 of 29)
489
Communications Guide
ADDR | NAME | RANGE | STEP | UNITS | FORMAT | DEFAULT |
|
|
|
|
|
|
|
2C58 | Analog Input 2 Trip Pickup | 0 to 1 | 1 | – | F130 | 0 |
|
|
|
|
|
|
|
2C59 | Analog Input 2 Trip Delay | 1 to 3000 | 1 | s | F2 | 1 |
|
|
|
|
|
|
|
2C5A | Analog Input 2 Name | 0 to 12 | 1 | – | F22 | _ |
|
|
|
|
|
|
|
ANALOG INPUT/OUTPUT / ANALOG INPUT 3 |
|
|
|
|
| |
|
|
|
|
|
|
|
2C80 | Analog Input 3 | 0 to 3 | 1 | – | F129 | 0 |
|
|
|
|
|
|
|
2C85 | Analog Input 3 Units | 0 to 6 | 1 | – | F22 | _ |
|
|
|
|
|
|
|
2C88 | Analog Input 3 Minimum | 1 | Units | F12 | 0 | |
|
|
|
|
|
|
|
2C8A | Analog Input 3 Maximum | 1 | Units | F12 | 100 | |
|
|
|
|
|
|
|
2C8C | Block Analog Input 3 From Online | 0 to 5000 | 1 | s | F1 | 0 |
|
|
|
|
|
|
|
2C8D | Analog Input 3 Alarm | 0 to 2 | 1 | – | F115 | 0 |
|
|
|
|
|
|
|
2C8E | Assign Alarm Relays | 1 to 4 | 1 | – | F50 | 16 |
|
|
|
|
|
|
|
2C8F | Analog Input 3 Alarm Level | 1 | Units | F12 | 10 | |
|
|
|
|
|
|
|
2C91 | Analog Input 3 Alarm Pickup | 0 to 1 | 1 | – | F130 | 0 |
|
|
|
|
|
|
|
2C92 | Analog Input 3 Alarm Delay | 1 to 3000 | 1 | s | F2 | 1 |
|
|
|
|
|
|
|
2C93 | Analog Input 3 Alarm Events | 0 to 1 | 1 | – | F105 | 0 |
|
|
|
|
|
|
|
2C94 | Analog Input 3 Trip | 0 to 2 | 1 | – | F115 | 0 |
|
|
|
|
|
|
|
2C95 | Assign Trip Relays | 0 to 3 | 1 | – | F50 | 1 |
|
|
|
|
|
|
|
2C96 | Analog Input 3 Trip Level | 1 | Units | F12 | 20 | |
|
|
|
|
|
|
|
2C98 | Analog Input 3 Trip Pickup | 0 to 1 | 1 | – | F130 | 0 |
|
|
|
|
|
|
|
2C99 | Analog Input 3 Trip Delay | 1 to 3000 | 1 | s | F2 | 1 |
|
|
|
|
|
|
|
2C9A | Analog Input 3 Name | 0 to 12 | 1 | – | F22 | _ |
|
|
|
|
|
|
|
ANALOG INPUT/OUTPUT / ANALOG INPUT 4 |
|
|
|
|
| |
|
|
|
|
|
|
|
2CC0 | Analog Input 4 | 0 to 3 | 1 | – | F129 | 0 |
|
|
|
|
|
|
|
2CC5 | Analog Input 4 Units | 0 to 6 | 1 | – | F22 | _ |
|
|
|
|
|
|
|
2CC8 | Analog Input 4 Minimum | 1 | Units | F12 | 0 | |
|
|
|
|
|
|
|
2CCA | Analog Input 4 Maximum | 1 | Units | F12 | 100 | |
|
|
|
|
|
|
|
2CCC | Block Analog Input 4 From Online | 0 to 5000 | 1 | s | F1 | 0 |
|
|
|
|
|
|
|
2CCD | Analog Input 4 Alarm | 0 to 2 | 1 | – | F115 | 0 |
|
|
|
|
|
|
|
2CCE | Assign Alarm Relays | 1 to 4 | 1 | – | F50 | 16 |
|
|
|
|
|
|
|
2CCF | Analog Input 4 Alarm Level | 1 | Units | F12 | 10 | |
|
|
|
|
|
|
|
2CD1 | Analog Input 4 Alarm Pickup | 0 to 1 | 1 | – | F130 | 0 |
|
|
|
|
|
|
|
2CD2 | Analog Input 4 Alarm Delay | 1 to 3000 | 1 | s | F2 | 1 |
|
|
|
|
|
|
|
2CD3 | Analog Input 4 Alarm Events | 0 to 1 | 1 | – | F105 | 0 |
|
|
|
|
|
|
|
2CD4 | Analog Input 4 Trip | 0 to 2 | 1 | – | F115 | 0 |
|
|
|
|
|
|
|
2CD5 | Assign Trip Relays | 0 to 3 | 1 | – | F50 | 1 |
|
|
|
|
|
|
|
2CD6 | Analog Input 4 Trip Level | 1 | Units | F12 | 20 | |
|
|
|
|
|
|
|
2CD8 | Analog Input 4 Trip Pickup | 0 to 1 | 1 | – | F130 | 0 |
|
|
|
|
|
|
|
2CD9 | Analog Input 4 Trip Delay | 1 to 3000 | 1 | s | F2 | 1 |
|
|
|
|
|
|
|
2CDA | Analog Input 4 Name | 0 to 12 | 1 | – | F22 | _ |
|
|
|
|
|
|
|
489 TESTING / SIMULATION MODE |
|
|
|
|
| |
|
|
|
|
|
|
|
2D00 | Simulation Mode | 0 to 3 | 1 | – | F138 | 0 |
|
|
|
|
|
|
|
2D01 | 0 to 300 | 1 | s | F1 | 15 | |
|
|
|
|
|
|
|
489 TESTING / |
|
|
|
|
| |
|
|
|
|
|
|
|
2D20 | 0 to 2000 | 1 | ⋅ CT | F3 | 0 | |
|
|
|
|
|
|
|
2D21 | 0 to 150 | 1 | ⋅ Rated | F3 | 100 | |
|
|
|
|
|
|
|
2D22 | 0 to 359 | 1 | ° | F1 | 0 | |
|
|
|
|
|
|
|
2D23 | 0 to 2000 | 1 | ⋅ CT | F3 | 0 | |
|
|
|
|
|
|
|
2D24 | 0 to 2000 | 1 | ⋅ CT | F3 | 0 | |
|
|
|
|
|
|
|
2D25 | 0 to 1000 | 1 | Volts | F2 | 0 | |
|
|
|
|
|
|
|
2D26 | 1 | °C | F4 | 40 | ||
|
|
|
|
|
|
|
2D27 | 1 | °C | F4 | 40 | ||
|
|
|
|
|
|
|
2D28 | 1 | °C | F4 | 40 | ||
|
|
|
|
|
|
|
2D29 | 1 | °C | F4 | 40 | ||
|
|
|
|
|
|
|
1, 2, 3 See Table footnotes on page 39
GE Multilin |
http://www.GEindustrial.com/multilin
37 |