489

 

 

 

 

Modbus Memory Map

 

Communications Guide

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 1: 489 Memory Map (Sheet 6 of 29)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ADDR

NAME

RANGE

STEP

UNITS

FORMAT

DEFAULT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

04AC

RTD #11 Temperature

–52 to 251

1

°C

F4

–52

 

 

 

 

 

 

 

 

 

04AD

RTD #12 Temperature

–52 to 251

1

°C

F4

–52

 

 

 

 

 

 

 

 

 

04C0

Hottest Stator RTD Temperature

–52 to 250

1

°F

F4

–52

 

 

 

 

 

 

 

 

 

04C1

RTD #1 Temperature

–52 to 251

1

°F

F4

–52

 

 

 

 

 

 

 

 

 

04C2

RTD #2 Temperature

–52 to 251

1

°F

F4

–52

 

 

 

 

 

 

 

 

 

04C3

RTD #3 Temperature

–52 to 251

1

°F

F4

–52

 

 

 

 

 

 

 

 

 

04C4

RTD #4 Temperature

–52 to 251

1

°F

F4

–52

 

 

 

 

 

 

 

 

 

04C5

RTD #5 Temperature

–52 to 251

1

°F

F4

–52

 

 

 

 

 

 

 

 

 

04C6

RTD #6 Temperature

–52 to 251

1

°F

F4

–52

 

 

 

 

 

 

 

 

 

04C7

RTD #7 Temperature

–52 to 251

1

°F

F4

–52

 

 

 

 

 

 

 

 

 

04C8

RTD #8 Temperature

–52 to 251

1

°F

F4

–52

 

 

 

 

 

 

 

 

 

04C9

RTD #9 Temperature

–52 to 251

1

°F

F4

–52

 

 

 

 

 

 

 

 

 

04CA

RTD #10 Temperature

–52 to 251

1

°F

F4

–52

 

 

 

 

 

 

 

 

 

04CB

RTD #11 Temperature

–52 to 251

1

°F

F4

–52

 

 

 

 

 

 

 

 

 

04CC

RTD #12 Temperature

–52 to 251

1

°F

F4

–52

 

 

 

 

 

 

 

 

 

 

METERING DATA / DEMAND METERING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

04E0

Current Demand

0 to 1000000

1

Amps

F12

0

 

 

 

 

 

 

 

 

 

 

 

04E2

MW Demand

0 to 2000000

1

MW

F13

0

 

 

 

 

 

 

 

 

 

 

 

04E4

Mvar Demand

0 to 2000000

1

Mvar

F13

0

 

 

 

 

 

 

 

 

 

 

 

04E6

MVA Demand

0 to 2000000

1

MVA

F13

0

 

 

 

 

 

 

 

 

 

 

 

04E8

Peak Current Demand

0 to 1000000

1

Amps

F12

0

 

 

 

 

 

 

 

 

 

 

 

04EA

Peak MW Demand

0 to 2000000

1

MW

F13

0

 

 

 

 

 

 

 

 

 

 

 

04EC

Peak Mvar Demand

0 to 2000000

1

Mvar

F13

0

 

 

 

 

 

 

 

 

 

 

 

04EE

Peak MVA Demand

0 to 2000000

1

MVA

F13

0

 

 

 

 

 

 

 

 

 

 

 

METERING DATA / ANALOG INPUTS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0500

Analog Input 1

–50000 to 50000

1

Units

F12

0

 

 

 

 

 

 

 

 

 

 

 

0502

Analog Input 2

–50000 to 50000

1

Units

F12

0

 

 

 

 

 

 

 

 

 

 

 

0504

Analog Input 3

–50000 to 50000

1

Units

F12

0

 

 

 

 

 

 

 

 

 

 

 

0506

Analog Input 4

–50000 to 50000

1

Units

F12

0

 

 

 

 

 

 

 

 

 

 

 

METERING DATA / SPEED

 

 

 

 

 

 

0520 Tachometer

0 to 7200

1

RPM

F1

0

LEARNED DATA / PARAMETER AVERAGES

0600

Average Generator Load

0 to 2000

1

%FLA

F1

0

 

 

 

 

 

 

 

0601

Average Negative Sequence Current

0 to 2000

1

%FLA

F1

0

 

 

 

 

 

 

 

0602

Average Phase-Phase Voltage

0 to 50000

1

V

F1

0

 

 

 

 

 

 

 

0603

Reserved

 

 

 

 

 

 

 

0604

Reserved

 

 

 

 

 

 

 

LEARNED DATA / RTD MAXIMUMS

 

 

 

 

 

 

 

 

 

 

 

 

0620

RTD #1 Maximum Temperature (Celsius)

–52 to 251

1

°C

F4

–52

 

 

 

 

 

 

 

0621

RTD #2 Maximum Temperature (Celsius)

–52 to 251

1

°C

F4

–52

 

 

 

 

 

 

 

0622

RTD #3 Maximum Temperature (Celsius)

–52 to 251

1

°C

F4

–52

 

 

 

 

 

 

 

0623

RTD #4 Maximum Temperature (Celsius)

–52 to 251

1

°C

F4

–52

 

 

 

 

 

 

 

0624

RTD #5 Maximum Temperature (Celsius)

–52 to 251

1

°C

F4

–52

 

 

 

 

 

 

 

0625

RTD #6 Maximum Temperature (Celsius)

–52 to 251

1

°C

F4

–52

 

 

 

 

 

 

 

0626

RTD #7 Maximum Temperature (Celsius)

–52 to 251

1

°C

F4

–52

 

 

 

 

 

 

 

0627

RTD #8 Maximum Temperature (Celsius)

–52 to 251

1

°C

F4

–52

 

 

 

 

 

 

 

0628

RTD #9 Maximum Temperature (Celsius)

–52 to 251

1

°C

F4

–52

 

 

 

 

 

 

 

0629

RTD #10 Maximum Temperature (Celsius)

–52 to 251

1

°C

F4

–52

 

 

 

 

 

 

 

062A

RTD #11 Maximum Temperature (Celsius)

–52 to 251

1

°C

F4

–52

 

 

 

 

 

 

 

062B

RTD #12 Maximum Temperature (Celsius)

–52 to 251

1

°C

F4

–52

 

 

 

 

 

 

 

0640

RTD #1 Maximum Temperature (Fahrenheit)

–52 to 251

1

°F

F4

–52

 

 

 

 

 

 

 

0641

RTD #2 Maximum Temperature (Fahrenheit)

–52 to 251

1

°F

F4

–52

 

 

 

 

 

 

 

0642

RTD #3 Maximum Temperature (Fahrenheit)

–52 to 251

1

°F

F4

–52

 

 

 

 

 

 

 

1, 2, 3 See Table footnotes on page 39

16

http://www.GEindustrial.com/multilin

GE Multilin

Page 20
Image 20