489

Communications Guide

Table 2: Data Formats (Sheet 5 of 12)

CODE

TYPE

DEFINITION

 

 

 

F127

Unsigned

ANALOG OUTPUT

 

16 bit

PARAMETER

 

integer

SELECTION

 

 

 

 

0

None

 

 

 

 

1

IA Output Current

 

 

 

 

2

IB Output Current

 

 

 

 

3

IC Output Current

 

 

 

 

4

Average Output Current

 

 

 

 

5

Negative Sequence

 

 

Current

 

 

 

 

6

Average Generator Load

 

 

 

 

7

Hottest Stator RTD

 

 

 

 

8

Hottest Bearing RTD

 

 

 

 

9

Ambient RTD

 

 

 

 

10

RTD #1

 

 

 

 

11

RTD #2

 

 

 

 

12

RTD #3

 

 

 

 

13

RTD #4

 

 

 

 

14

RTD #5

 

 

 

 

15

RTD #6

 

 

 

 

16

RTD #7

 

 

 

 

17

RTD #8

 

 

 

 

18

RTD #9

 

 

 

 

19

RTD #10

 

 

 

 

20

RTD #11

 

 

 

 

21

RTD #12

 

 

 

 

22

AB Voltage

 

 

 

 

23

BC Voltage

 

 

 

 

24

CA Voltage

 

 

 

 

25

Average Voltage

 

 

 

 

26

Volts/Hertz

 

 

 

 

27

Frequency

 

 

 

 

28

Third Harmonic Neutral

 

 

Voltage

 

 

 

 

29

Power Factor

 

 

 

 

30

Reactive Power (Mvar)

 

 

 

 

31

Real Power (MW)

 

 

 

 

32

Apparent Power (MVA)

 

 

 

 

33

Analog Input 1

 

 

 

 

34

Analog Input 2

 

 

 

 

35

Analog Input 3

 

 

 

 

36

Analog Input 4

 

 

 

 

37

Tachometer

 

 

 

 

38

Thermal Capacity Used

 

 

 

 

39

Current Demand

 

 

 

 

40

Mvar Demand

 

 

 

 

41

MW Demand

 

 

 

 

42

MVA Demand

 

 

 

F128

Unsigned

OVERCURRENT CURVE

 

16 bit

STYLE SELECTION

 

integer

 

 

 

 

 

0

ANSI Extremely Inverse

 

 

 

 

1

ANSI Very Inverse

 

 

 

 

2

ANSI Normally Inverse

 

 

 

 

3

ANSI Moderately Inverse

 

 

 

 

4

IEC Curve A (BS142)

 

 

 

Modbus Memory Map

Table 2: Data Formats (Sheet 6 of 12)

CODE

TYPE

DEFINITION

 

 

 

F128

5

IEC Curve B (BS142)

ctd.

 

 

6

IEC Curve C (BS142)

 

 

 

 

 

7

IEC Short Inverse

 

 

 

 

8

IAC Extremely Inverse

 

 

 

 

9

IAC Very Inverse

 

 

 

 

10

IAC Inverse

 

 

 

 

11

IAC Short Inverse

 

 

 

 

12

FlexCurve™

 

 

 

 

13

Definite Time

 

 

 

FC129

Unsigned

ANALOG INPUT

 

16 bit

SELECTION

 

integer

 

 

 

 

 

0

Disabled

 

 

 

 

1

4 to 20 mA

 

 

 

 

2

0 to 20 mA

 

 

 

 

3

0 to 1 mA

 

 

 

F130

Unsigned

PICKUP TYPE

 

16 bit

 

 

integer

 

 

 

 

 

0

Over

 

 

 

 

1

Under

 

 

 

FC131

Unsigned

INPUT SWITCH

 

16 bit

STATUS

 

integer

 

 

 

 

 

0

Closed

 

 

 

 

1

Open

 

 

 

F132

Unsigned

TRIP COIL

 

16 bit

SUPERVISION STATUS

 

integer

 

 

 

 

 

0

No Coil

 

 

 

 

1

Coil

 

 

 

F133

Unsigned

GENERATOR STATUS

 

16 bit

 

 

integer

 

 

 

 

 

0

Offline

 

 

 

 

1

Offline

 

 

 

 

2

Online

 

 

 

 

3

Overload

 

 

 

 

4

Tripped

 

 

 

F134

Unsigned

CAUSE OF EVENT /

 

16 bit

CAUSE OF LAST TRIP

 

integer

 

 

 

 

 

0

No Event

 

 

 

 

1

General Switch A Trip

 

 

 

 

2

General Switch B Trip

 

 

 

 

3

General Switch C Trip

 

 

 

 

4

General Switch D Trip

 

 

 

 

5

General Switch E Trip

 

 

 

 

6

General Switch F Trip

 

 

 

 

7

General Switch G Trip

 

 

 

 

8

Sequential Trip

 

 

 

 

9

Tachometer Trip

 

 

 

 

10

Unknown Trip

 

 

 

 

11

Unknown Trip

 

 

 

 

12

Overload Trip

 

 

 

 

13

Unknown Trip

 

 

 

 

14

Neutral Overvoltage Trip

 

 

 

 

15

Neutral Undervoltage

 

 

(3rd Harmonic) Trip

 

 

 

42

http://www.GEindustrial.com/multilin

GE Multilin

Page 46
Image 46
GE 1601-0149-A2 Analog Output, Parameter, Overcurrent Curve, Style Selection, Analog Input, Pickup Type, Input Switch