Lincoln 1600 service manual Troubleshooting Guide, Gas Ovens, Symptom, Possible Cause, Evaluation

Models: 1600

1 28
Download 28 pages 62.83 Kb
Page 4
Image 4
TROUBLESHOOTING GUIDE

TROUBLESHOOTING GUIDE

GAS OVENS

MODEL 1600-000-A / NATURAL GAS / 120 VAC / 60 HZ / 1 PHASE

MODEL 1601-000-A / L.P. GAS / 120 VAC / 60 HZ / 1 PHASE

NOTE: When checking components on left side of unit, be sure to check for proper connections in power connector, (marked P. C. on Schematic Diagram.) located inside motor cover.

 

SYMPTOM

 

 

POSSIBLE CAUSE

 

 

EVALUATION

 

 

 

 

 

 

 

 

Oven fan will not run

 

Incoming Power

 

Check breakers, reset if required. Check power plug to be sure

 

 

 

 

Supply

 

it is firmly in receptacle. Measure the incoming power/call

 

 

 

 

 

 

 

power company if needed.

 

 

 

 

 

 

 

 

 

 

 

Main Fan Switch

 

Check continuity between switch terminals.

 

 

 

 

Fuse, 10 Amp

 

Check, replace if necessary.

 

 

 

 

Fuse Holder

 

Check, replace if necessary.

 

 

 

 

Fuse 3A

 

Check, replace if necessary.

 

 

 

 

Fuse holder

 

Check, replace if necessary.

 

 

 

 

Hi Limit Thermostat(s)

 

Check for voltage on both sides of the switch. Terminals are

 

 

 

 

Control Box

 

normally closed. If open, reset and test oven for proper

 

 

 

 

 

 

 

operation. If thermostat will not hold and control box

 

 

 

 

 

 

 

temperature is not exceeding 140°F (60°C), replace

 

 

 

 

 

 

 

thermostat.

 

 

 

 

Oven Power Relay

 

Check for 120 VAC to the relay coil. If voltage is not present,

 

 

 

 

 

 

 

trace wiring back to the control box hi-limit. If voltage is

 

 

 

 

 

 

 

present, check to insure contacts are closing. Check for 120

 

 

 

 

 

 

 

VAC supplied to terminal #2 of the relay.

 

 

 

 

Main Fan Motor

 

Check for opens, shorts, or grounds. WITH POWER OFF turn

 

 

 

 

 

 

 

fan blade to check for locked rotor.

 

 

 

 

Capacitor

 

Check for shorts or grounds.

 

 

 

 

 

 

 

WARNING: Capacitor has a stored charge, discharge before

 

 

 

 

 

 

 

testing.

 

No control box cooling

 

Incoming Power

 

Check main circuit breakers, reset if required, call power

 

 

 

 

 

 

 

company if needed.

 

 

 

 

Main Fan Switch

 

Check continuity between switch terminals

 

 

 

 

Fuse 3 amp.

 

Check, replace if necessary.

 

 

 

 

Fuse Holder

 

Check, replace if necessary.

 

 

 

 

Hi Limit Thermostat(s)

 

Check for voltage on both sides of the switch. Terminals are

 

 

 

 

Control Box

 

normally closed. If open, reset and test oven for proper

 

 

 

 

 

 

 

operation. If thermostat will not hold and control box

 

 

 

 

 

 

 

temperature is not exceeding 140°F (60°C), replace

 

 

 

 

 

 

 

thermostat.

 

 

 

 

Cooling Fan(s)

 

120 VAC should now be at the fan motor. If voltage is present,

 

 

 

 

 

 

 

check motors for shorts or opens. WITH POWER OFF:

 

 

 

 

 

 

 

Check for locked rotor.

 

No automatic control

 

Incoming Power

 

Check circuit breakers, reset if required. Call the power

 

box cooling

 

Supply

 

company if needed.

 

 

 

 

Cooling Fan

 

Check the cooling fan thermostat. (Thermostat closes at

 

 

 

 

Thermostat(s)

 

120°F and opens at 100°F). With the cooling fan thermostat

 

 

 

 

 

 

 

preheated, check for continuity. If switch is open, replace.

 

 

 

 

Fuse, 3 amp

 

Check, replace if necessary

 

 

 

 

Fuse Holder

 

Check, replace if necessary

 

 

 

 

Hi Limit Thermostat(s)

 

Check for voltage on both sides of the switch. Terminals are

 

 

 

 

Control Box

 

normally closed. If open, reset and test oven for proper

 

 

 

 

 

 

 

operation. If thermostat will not hold and control box

 

 

 

 

 

 

 

temperature is not exceeding 140°F (60°C), replace

 

 

 

 

 

 

 

thermostat.

4

Low Profile – 1600-000-A Advantage Series Service Manual – Domestic

Page 4
Image 4
Lincoln 1600 service manual Troubleshooting Guide, Gas Ovens, Symptom, Possible Cause, Evaluation