TROUBLESHOOTING GUIDE
GAS OVENS
MODEL
MODEL
NOTE: When checking components on left side of unit, be sure to check for proper connections in power connector, (marked P. C. on Schematic Diagram.) located inside motor cover.
| SYMPTOM |
|
| POSSIBLE CAUSE |
|
| EVALUATION |
|
|
|
|
|
|
| |||
| Oven fan will not run |
| Incoming Power |
| Check breakers, reset if required. Check power plug to be sure | |||
|
|
|
| Supply |
| it is firmly in receptacle. Measure the incoming power/call | ||
|
|
|
|
|
|
| power company if needed. | |
|
|
|
|
|
|
| ||
|
|
|
| Main Fan Switch |
| Check continuity between switch terminals. | ||
|
|
|
| Fuse, 10 Amp |
| Check, replace if necessary. | ||
|
|
|
| Fuse Holder |
| Check, replace if necessary. | ||
|
|
|
| Fuse 3A |
| Check, replace if necessary. | ||
|
|
|
| Fuse holder |
| Check, replace if necessary. | ||
|
|
|
| Hi Limit Thermostat(s) |
| Check for voltage on both sides of the switch. Terminals are | ||
|
|
|
| Control Box |
| normally closed. If open, reset and test oven for proper | ||
|
|
|
|
|
|
| operation. If thermostat will not hold and control box | |
|
|
|
|
|
|
| temperature is not exceeding 140°F (60°C), replace | |
|
|
|
|
|
|
| thermostat. | |
|
|
|
| Oven Power Relay |
| Check for 120 VAC to the relay coil. If voltage is not present, | ||
|
|
|
|
|
|
| trace wiring back to the control box | |
|
|
|
|
|
|
| present, check to insure contacts are closing. Check for 120 | |
|
|
|
|
|
|
| VAC supplied to terminal #2 of the relay. | |
|
|
|
| Main Fan Motor |
| Check for opens, shorts, or grounds. WITH POWER OFF turn | ||
|
|
|
|
|
|
| fan blade to check for locked rotor. | |
|
|
|
| Capacitor |
| Check for shorts or grounds. | ||
|
|
|
|
|
|
| WARNING: Capacitor has a stored charge, discharge before | |
|
|
|
|
|
|
| testing. | |
| No control box cooling |
| Incoming Power |
| Check main circuit breakers, reset if required, call power | |||
|
|
|
|
|
|
| company if needed. | |
|
|
|
| Main Fan Switch |
| Check continuity between switch terminals | ||
|
|
|
| Fuse 3 amp. |
| Check, replace if necessary. | ||
|
|
|
| Fuse Holder |
| Check, replace if necessary. | ||
|
|
|
| Hi Limit Thermostat(s) |
| Check for voltage on both sides of the switch. Terminals are | ||
|
|
|
| Control Box |
| normally closed. If open, reset and test oven for proper | ||
|
|
|
|
|
|
| operation. If thermostat will not hold and control box | |
|
|
|
|
|
|
| temperature is not exceeding 140°F (60°C), replace | |
|
|
|
|
|
|
| thermostat. | |
|
|
|
| Cooling Fan(s) |
| 120 VAC should now be at the fan motor. If voltage is present, | ||
|
|
|
|
|
|
| check motors for shorts or opens. WITH POWER OFF: | |
|
|
|
|
|
|
| Check for locked rotor. | |
| No automatic control |
| Incoming Power |
| Check circuit breakers, reset if required. Call the power | |||
| box cooling |
| Supply |
| company if needed. | |||
|
|
|
| Cooling Fan |
| Check the cooling fan thermostat. (Thermostat closes at | ||
|
|
|
| Thermostat(s) |
| 120°F and opens at 100°F). With the cooling fan thermostat | ||
|
|
|
|
|
|
| preheated, check for continuity. If switch is open, replace. | |
|
|
|
| Fuse, 3 amp |
| Check, replace if necessary | ||
|
|
|
| Fuse Holder |
| Check, replace if necessary | ||
|
|
|
| Hi Limit Thermostat(s) |
| Check for voltage on both sides of the switch. Terminals are | ||
|
|
|
| Control Box |
| normally closed. If open, reset and test oven for proper | ||
|
|
|
|
|
|
| operation. If thermostat will not hold and control box | |
|
|
|
|
|
|
| temperature is not exceeding 140°F (60°C), replace | |
|
|
|
|
|
|
| thermostat. |