| are no obstructions, replace gas control valves. |
Flame will not stay lit | Hot Surface Igniter | The ignition control will keep the gas control valves energized |
|
| for 6 seconds. At the end of 6 seconds, the hot surface igniter |
|
| must sense a flame, or, the ignition control will go into lockout. |
|
| (The ignition control requires a minimum of 0.8 microamps |
|
| D.C.) To check the flame sensing operation, connect a digital |
|
| multimeter (capable of measuring D.C. |
|
| the "ground" terminal on ignition control and the ground lead. |
|
| NOTE: This is a current measurement and the meter must be |
|
| connected in series. If these readings are not achieved, check |
|
| bypass orifice for obstructions, if bypass orifice is clear, |
|
| replace the hot surface igniter. |
|
| NOTE: The D.C. micro amp test must be conducted with the |
|
| oven in low flame (bypass) operation. Turn the temperature |
|
| control to its lowest setting. |
| Power Supply | If there is sufficient |
|
| stay lit, check for proper polarity of the 120 VAC power supply |
| Ignition Control | If there is sufficient |
|
| polarity is correct, but the flame will not stay lit, replace the |
|
| ignition control. |
|
| NOTE: Check for proper ground connection of the ignition |
|
| control. |
| NOTE: Flame should |
|
| be lit at this time. |
|
Low flame is on, but | Temperature Control | Check for 120 VAC at terminal #7 to neutral on temperature |
no main flame |
| control. If no voltage, trace voltage back to fuse holder. Turn |
|
| the temperature adjustment knob to maximum temperature |
|
| position and check for 120 VAC at the load terminal #8 and |
|
| neutral. If 120 VAC is present and unit is not heating, refer to |
|
| "Temperature Solenoid Valve" for next check. If 120 VAC is |
|
| not present, proceed. |
| Thermocouple Probe | WITH POWER ON AND THERMOCOUPLE LEADS |
|
| ATTACHED TO THE TEMPERATURE CONTROL BOARD: |
|
| Measure the D.C. millivolt output of these leads. Refer to |
|
| thermocouple chart on page 17 for proper readings. If these |
|
| readings are not achieved, replace the thermocouple. |
| Temperature Set | Disconnect the potentiometer leads Disconnect the pot from |
| Potentiometer | the board. Place ohm meter test leads on the blue and green |
|
| pot leads. Reading should be 1 K ohms. Place meter leads |
|
| across the blue and purple pot leads and rotate knob from high |
|
| to low. Repeat on green and purple leads. Check for even |
|
| rise and fall of ohms reading to insure that there are no open |
|
| or dead spots in the potentiometer. Check each lead to |
|
| ground for shorts. Replace pot if it does not meet the above |
|
| test |
| Temperature Solenoid | If 120 VAC is present on the temperature control board at load |
| Valve | terminal #8 to neutral, check for voltage at temperature |
|
| regulation valve. If voltage is present, listen for valve to open |
|
| and close. Also check for opens or shorts in the coil. Replace |
|
| as necessary. |
6 | Low Profile – |