REMOVAL, INSTALLATION & ADJUSTMENTS

MODEL SERIES 1600 ADVANTAGE

CAUTION !

BEFORE REMOVING OR INSTALLING ANY COMPONENT IN THE IMPINGER

OVEN BE SURE TO DISCONNECT ELECTRICAL POWER AND GAS SUPPLY

BURNER CONTROL - HONEYWELL - REPLACEMENT

A.Remove appropriate control box cover.

B.Remove wires from control, note wire number and location for re-assembly.

C.Remove four (4) screws from control and replace.

D.Reassemble in reverse order and check system operation.

BURNER BLOWER MOTOR - REPLACEMENT

A.Remove appropriate control box cover.

B.Unplug motor connector.

C.Remove three (3) screws from blower tube at burner housing.

D.Remove air shutter assy. from old motor for installation on new motor assy.

E.Reassemble in reverse order and check system operation.

NOTE: CHECK AIR SHUTTER ADJUSTMENT- should be set at 1/2 open.

HOT SURFACE IGNITER - REPLACEMENT

A.Remove appropriate control box cover.

B.Disconnect gas line at union.

C.Remove four (4) nuts from burner orifice bracket.

D.Remove tube for bypass flame.

E.Unplug connector at burner housing.

F.Remove three (3) screws from burner housing end cap and remove hot surface igniter and burner tube assy.

G.Replace igniter assembly and reassemble in reverse order. CAUTION: USE CARE NOT TO DAMAGE NEW IGNITER.

NOTE: Check all gas line fittings for leaks. Make sure connector is seated properly.

BURNER INDICATOR LIGHT (GAS) - REPLACEMENT

A.Remove control box cover

B.Remove two (2) wires from light housing.

C.Slide light housing sideways to remove.

D.Reassemble in reverse order and check system operation.

CONVEYOR CONTROL POTENTIOMETER (10K OHM) - REPLACEMENT

A.Remove control box cover

B.Loosen two (2) allen screws and remove knob by sliding off shaft.

C.Remove nut from potentiometer shaft and push out.

D.Unplug wire connector from conveyor control board.

E.Reassemble in reverse order and check system operation.

F.Recalibrate conveyor control board.

CONVEYOR CONTROL BOARD - REPLACEMENT

A.Shut off power at main breaker.

B.Remove control panel top and front cover.

C.Disconnect wiring (push on connectors) from control board, note proper location of connectors for reinstallation and exchange boards on the mounting bracket before reinstallation.

Low Profile – 1600-000-A Advantage Series Service Manual – Domestic