14 en Diagrams | Control Panel |
|
|
3.4 | SDI Devices Wiring Diagrams |
3.4.1 | D9412GV4 SDI and Zonex Devices System Wiring Diagram |
Figure 3.4: D9412GV4 System Wiring Diagram, SDI and Zonex Devices
Callout ᅳ Description | Callout ᅳ Description | ||
|
|
|
|
1 | ᅳ Up to 16 supervised D1265, D1255 (all versions), | 6 | ᅳ Zonex 1: 15 D8128Ds maximum1 |
D1255RB, D1256RB Keypads, or D1257RB Fire Annunciators, |
|
| |
or up to 8 supervised D1260 Keypads (all versions) (maximum |
|
| |
16 supervised, maximum 32 unsupervised) |
|
| |
|
|
| |
2 | ᅳ Up to 8 D9210C Access Control Interface Modules | 7ᅳ Zonex 2: 15 D8128Ds maximum1 | |
|
|
|
|
3 | ᅳ Up to 2 B426/B420/DX4020 or | 8 | ᅳ Zonex 1: Up to 8 D129s maximum1 |
Interface Modules |
|
| |
|
|
|
|
4 | ᅳ D8125 POPEX Module | 9 | ᅳ Zonex 2: Up to 8 D8129s maximum1 |
|
|
|
|
5 | ᅳ Up to 119 D9127U/T POPITs |
|
|
|
|
|
|
1The number of D8129 OctoRelays that can be connected to each Zonex terminal on the control panel is limited by the number of D8128D OctoPOPITs connected to the same terminal. Refer to the D8128D Installation Guide (P/N: F01U070537) or the D8129 Operation and Installation Guide (P/N: F01U036302) for specific information.
2012.12 02 F.01U.265.462 | UL Installation Instructions | Bosch Security Systens, Inc. |