6 en InstallationControl Panel
i | Notice! | |
Electromagnetic interference (EMI) can cause problems on long wire runs. | ||
|
Figure 2.1: Enclosure Mounting
Callout - Description
| 1 | - Point chart label |
|
|
|
| 2 | - Mounting skirt hooks (2) |
|
|
|
| 3 | - Module mounting holes (12) |
|
|
|
| 4 | - Tamper switch mounting holes (5) |
|
|
|
| 5 | - Skirt mounting hole (1) |
|
|
|
| 6 | - Enclosure mounting holes (5) |
|
|
|
| 7 | - Mounting skirt hook holes (2) |
|
|
|
| 8 | - Back of the control panel |
|
|
|
| 9 | - Lock down tab |
|
| |
2.4 | Installing the Control Panel | |
| 1. | Place the control panel over the inside back of the enclosure, aligning the large |
|
| rectangular openings of the mounting skirt with the mounting hooks of the enclosure. |
|
| Slide the control panel down so that it hangs on the hooks. Refer to Figure 2.1. |
| 2. | Remove the tape from the #6 x |
|
| The screw passes through the mounting tab and into the skirt mounting hole in the |
|
| enclosure. Tighten the screw to secure the control panel in the enclosure. |
| 3. | Connect earth ground to the control panel before making any other connections. Refer to |
|
| Connecting Earth Ground. |
2012.12 02 F.01U.265.462 | UL Installation Instructions | Bosch Security Systens, Inc. |