2 INSTALLATION AND CONNECTIONS

2 INSTALLATION AND CONNECTIONS

Unpacking

After unpacking, immediately report any damage to the delivering carrier or dealer. Keep the shipping car- tons.

Grounding

To prevent electrical shock, television interference (TVI), broadcast interference (BCI) and other prob- lems, ground the transceiver through the GROUND terminal on the rear panel.

For best results, connect a heavy gauge wire or strap to a long earth-sunk copper rod. Make the distance between the GROUND terminal and ground as short as possible.

For a description and a diagram of accessory equip- ment included with the IC-706MKIIG, see UNPACK- ING on p. ii of this manual.

RWARNING: NEVER connect the [GND] ter- minal to a gas or electric pipe, since the connection could cause an explosion or electric shock.

Antenna

Select antenna(s), such as a well-matched 50 antenna, and feedline. The transmission line should be a coaxial cable. 1.5 : 1 or better of Voltage Standing Wave Ratio (VSWR) is recommended for your required band. Of course, the transmission line should be a coaxial cable.

CAUTION: Protect your transceiver from lightning using a lightning arrestor.

ANTENNA SWR

Each antenna is tuned for a specified frequency range and SWR may be increased out-of-range. When the SWR is higher than approx. 2.0 : 1, the transceiver’s power drops to protect the final transis- tors. In this case, an optional antenna tuner is useful to match the transceiver and antenna. Low SWR allows full power for transmitting even when using the antenna tuner. The IC-706MKIIG has an SWR meter to monitor the antenna SWR continuously.

PL-259 CONNECTOR INSTALLATION EXAMPLE

 

30 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Coupling ring

10 mm (soft solder)

10 mm

Soft

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

solder

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1–2 mm

(10 mm 38 in)

Slide the coupling ring down. Strip the cable jacket and soft solder.

Strip the cable as shown at left. Soft solder the center con- ductor.

solder solder Slide the connector ■Unpacking body on and solder it.

Screw the coupling ring onto the connector body.

9