Icom IC-706MKIIG Remote Jack Ci-Vinformation, DCI-Vconnection example, DData format, CT-17

Models: I706MKTMG IC-706MKIIG

1 75
Download 75 pages 32.92 Kb
Page 48
Image 48
 6 REMOTE JACK (CI-V) INFORMATION

DCI-V connection example 6 REMOTE JACK (CI-V) INFORMATION

DCI-V connection example

The transceiver can be connected through an option- al CT-17 CI-V LEVEL CONVERTER to a personal comput- er equipped with an RS-232C port. The Icom Communication interface-V (CI-V) controls the follow- ing functions of the transceiver.

Up to four Icom CI-V transceivers or receivers can be connected to a personal computer equipped with an RS-232C port. See p. 55 for setting the CI-V condition using initial set mode.

9–15 V DC

CT-17

Personal

computer

IC-706MKIIG

DData format

The CI-V system can be operated using the following data formats. Data formats differ according to com- mand numbers. A data area is added for some com- mands.

CONTROLLER TO IC-706MKIIG

FE FE 58 E0 Cn Sc Data area FD

OK MESSAGE TO CONTROLLER

FE FE 58 E0 FB FD

Preamble code (fixed)

Transceiver’s default address

Controller’s default address

Command number (see table at right)

Sub command number (see table at right)

BCD code data for frequency or memory number entry

End of message code (fixed)

Preamble code (fixed)

Transceiver’s default address

Controller’s default address

OK code (fixed)

End of message code (fixed)

IC-706MKIIG TO CONTROLLER

FE FE E0 58 Cn Sc Data area FD

NG MESSAGE TO CONTROLLER

FE FE 58 E0 FA FD

Preamble code (fixed)

Controller’s default address

Transceiver’s default address

Command number (see table at right)

Sub command number (see table at right)

BCD code data for frequency or memory number entry

End of message code (fixed)

Preamble code (fixed)

Transceiver’s default address

Controller’s default address

NG code (fixed)

End of message code (fixed)

45

Page 48
Image 48
Icom IC-706MKIIG, I706MKTMG instruction manual Remote Jack Ci-Vinformation, DCI-Vconnection example, DData format, CT-17