Image 54
6AUTO OFF (auto power OFF)

7 SET MODE

6AUTO OFF (auto power OFF)

The auto power OFF function can be used to auto- matically turn the transceiver OFF after a specified time of operation. This item can be set to 30 min., 60 min., 90 min., 120 min., or OFF.

Auto power OFF

Auto power OFF set to

deactivates. (default)

20 min.

7 RF/SQL (SQL/AUTO/RF•SQL)

The [RF/SQL] control can be set as the squelch con- trol (default), the RF/squelch control (USA version default) or automatic (acts as squelch in FM/WFM/AM modes; as RF in SSB/CW/RTTY modes). (See p. 22)

The [RF/SQL] control functions as RF gain control only.

The [RF/SQL] control functions as squelch control only.

8SUBDIAL (Subdial function)

When this item is set to “rit,” pushing [RIT/SUB] turns the RIT function ON (lights red)—rotating [M- CH] changes the RIT frequency; when this item is set to “Freq,” pushing [RIT/SUB] turns the sub dial func- tion ON (lights green)—rotating [M-CH] changes the operating frequency. Note that in FM, WFM and AM modes, pushing [RIT/SUB] always selects the sub dial function (lights green), regardless of this setting.

Pushing [RIT/SUB]

Pushing [RIT/SUB]

selects the RIT function

selects the sub dial function.

(default).

 

9 OPT. FIL 1 (optional filter)

When an optional filter is installed, this selection is necessary, otherwise the filters cannot be selected. Selections available are FL-100, FL-101, FL-103, FL-223, FL-232 and none (default). See p. 22 for usable filters for each mode and see p. 60 for filter installation.

No filters are selected

FL-223 (for LSB/USB mode)

(default).

is selected.

10 OPT. FIL 2 (optional filter)

When an optional filter is installed, this selection is necessary, otherwise the filters cannot be selected. Selections available are FL-100, FL-101, FL-103, FL-223, FL-232 and none (default). See p. 22 for usable filters for each mode and see p. 60 for filter installation.

No filters are selected

FL-223 (for LSB/USB mode)

(default).

is selected.

11PEAK HOLD (peak hold)

When the peak hold function is ON, the highest acti- vated segment of the meter remains visible for 0.5 sec.; when OFF, the meter functions normally.

Peak hold ON

Peak hold OFF

(default)

 

51