Lincoln 3240-2 Chamber, Drive, Constant, Length, Type, Dayton, Gleason, AVERY 60Hz, AVERY 50Hz

Models: 3240-2 3262 3270-2

1 40
Download 40 pages 14.33 Kb
Page 23
Image 23
CHAMBER

CONVEYOR CONTROL – PROGRAMMING

1.Determine which brand of motor is connected to the conveyor control.

2.Determine which type of dart conveyor control is installed in the oven. Looking at the face of the control, the old style control will have “up” and “down” keys only. The new style Dart conveyor control will have “up”, “down” and “enter” keys.

3.Determine the type of drive, direct, 10/15 chain reduction or right angle drive.

4.Determine the bake chamber size, 40”, 62” or 70”.

“DART” Conveyor control with “UP” and “DOWN” keys only (OLD STYLE).

DIP switches

1.Remove control box cover.

2.Remove top cover from conveyor control. Make sure that all DIP switches are in the OFF position.

3.Turn oven on, turn conveyor on. Set switch #7 to ON position. Display should read “PROG”.

4.Set switch #4 to ON position to set time mode. Press “UP” or “DOWN” keys to set value at :05. Set switch #4 to OFF, display should read “PROG” and a colon should be lit.

5.Set switch #1 to ON position to set constant. Use the “UP” or “DOWN” keys to set the following:

CHAMBER

DRIVE

CONSTANT

CONSTANT

CONSTANT

LENGTH

TYPE

DAYTON

GLEASON

GLEASON

 

 

 

AVERY 60Hz.

AVERY 50Hz.

40”

Direct

2:00

2:25

2:17

 

10/15 chain reduction

3:01

 

 

 

Right angle motor

1:31

 

 

62”

Direct

3:07

3:45

3:33

 

10/15 chain reduction

4:40

 

 

 

Right angle motor

2:22

 

 

70”

Direct

3:31

4:14

 

 

10/15 chain reduction

5:16

 

 

 

Right angle motor

2:40

 

 

6.Set switch #1 to OFF position, display should read “PROG”.

7.Set switch #2 to ON position to set minimum setting. Use “UP” or “DOWN” keys to set to 2:15. Set switch #2 to OFF position, display should read “PROG”.

8.Set switch #3 to ON position, to set maximum setting. Use “UP” or “DOWN” keys to set to 16:00. Set switch #3 to OFF position, display should read ”PROG”.

9.Set switch #7 to OFF position. Programming is complete.

10.Reassemble in reverse order and check system operation.

Impinger X2 – Analog Service Manual – Dom & Int’l

23

Page 23
Image 23
Lincoln 3240-2, 3270-2, 3262 service manual Chamber, Drive, Constant, Length, Type, Dayton, Gleason, AVERY 60Hz, AVERY 50Hz