CONVEYOR CONTROL – PROGRAMMING – GLEASON AVERY MOTOR, DIRECT DRIVE
Jumper
“DART” Conveyor control with “UP”, “DOWN” and “ENTER” keys.
15.Remove control box cover.
16.Remove top cover from conveyor control. Locate program jumper on conveyor control and set jumper to the “ON” position.
17.Turn oven on, turn conveyor on. Press and hold the “ENTER” key until the Parameter Selection Mode is entered (display will indicate “P 0”).
18.Using the “UP” or “DOWN” keys, select the parameters to be changed (See chart below). When the parameter is selected, press “ENTER”. Use the “UP” or “DOWN” keys to set the desired parameter. Press “ENTER” to save the changes.
19.After all parameters are programmed, select parameter 0 and press the “ENTER” key to return to the running mode.
20.Set program jumper on conveyor control to “OFF”.
21.Reassemble in reverse order and check system operation.
Parameter | 40” Oven | 62” Oven | 70” Oven | Explanation |
10 | 2 | 2 | 2 | Time Mode Setting (MM:SS) |
20 | 135 | 135 | 135 | Display minimum setting (value is in seconds) |
21 | 960 | 960 | 960 | Display maximum setting (value is in seconds) |
30 | 135 | 135 | 135 | Display setting at reference RPM, parameter 31 |
31 | 1933 | 2997 | 3383 | RPM at which display reference, should be displayed |
32 | 1 | 1 | 1 | Pulses per revolution of shaft encoder or pickup |
50 | 7 | 7 | 7 | Activate alarm when pickup stalled |
53 | 1 | 1 | 1 | Alarm flash enabled |
98 | 5 | 5 | 5 | Save parameter settings to user default area |
26 | Impinger X2 – Analog Service Manual – Dom & Int’l |