1111 North Hadley Road P.O. Box
Lincoln Foodservice Products, Inc
Technical Service Hot Line
Fort Wayne, Indiana Phone 800 374-3004 Fax
SEQUENCE OF OPERATION IMPINGER X2 OVENS
SEQUENCE OF OPERATION IMPINGER X2 OVENS
3240-2
SCHEMATIC DIAGRAM
MODEL 3240-2, 3262-2, 3270-260 HZ
MODEL 3240-2, 3262-2, 3270-250 HZ
SCHEMATIC DIAGRAM
TROUBLESHOOTING GUIDE
present, trace wiring back to the oven fan switch
Check for 120VAC to the switch, if no voltage is
Switch, burner
Air pressure switch
control to maximum temperature and check for
obstructions also check for frayed or broken wire
Electronic temperature
WITH POWER ON AND THERMOCOUPLE LEADS
Power supply
Temperature regulation valve
Replace temperature regulation valve as needed
incoming power, call power co. if needed
Check for a steady 120VAC supply to the conveyor
Repair or replace conveyor components as needed
Conveyor speed varying or
intermittent
TROUBLESHOOTING GUIDE
3240-2
Check for supply voltage to the burner control at
Thermostat, hi-limit
replace hi-limitthermostat
burner control. If voltage is present, proceed
proper polarity of the power supply
amps in series between the flame sensor wire
sensor wire and connections
Check for supply voltage at terminal #7 on burner
pressure, replace the valve
supply voltage to terminal #20 on the electronic
If voltage is not present, proceed
If supply voltage is present on the electronic
switch as needed
Check for supply voltage to conveyor control at
Check for a steady supply voltage to the conveyor
voltage is present, trace wiring back to conveyor
IMPINGER X2 SERIES OVENS
REMOVAL, INSTALLATION & ADJUSTMENTS
9.Remove burner tube bracket and Burner tube
FUSE HOLDER - REPLACEMENT
RELAY, MAIN FAN, - REPLACEMENT
TIMER, 30 MINUTE COOL DOWN - REPLACEMENT
SWITCH, ON/OFF - REPLACEMENT
AIR PRESSURE SWITCH - ADJUSTMENT
BURNER CONTROL - REPLACEMENT
AIR PRESSURE SWITCH - REPLACEMENT
3.Seal adjustment screw with nail polish
TEMPERATURE REGULATION VALVE - REPLACEMENT
HAIRPIN SWITCH THERMOCOUPLE - REPLACEMENT
THERMOSTAT, HI-LIMIT- REPLACEMENT
GAS VALVE - REPLACEMENT
SPARK IGNITER - REPLACEMENT
MAIN BURNER ORIFICE - REPLACEMENT
PILOT ORIFICE - REPLACEMENT
CONVEYOR MOTOR - REPLACEMENT
1.Shut off power at main breaker
HALL EFFECT SENSOR - REPLACEMENT
CONVEYOR CONTROL - REPLACEMENT
1.Shut off power at main breaker
CONSTANT
CHAMBER
DRIVE
CONSTANT
Display maximum setting value is in seconds
Time Mode Setting MM SS
Display minimum setting value is in seconds
Display setting at reference RPM, parameter
Time Mode Setting MM SS
8.Remove control box cover
1894
Display minimum setting value is in seconds
2997
15.Remove control box cover
1933
3383
This page intentionally left blank
IMPINGER X2 OVENS
GENERAL VIEW
Page
OVEN CAVITY
IMPINGER X2 OVENS
Page
CONTROL BOX
IMPINGER X2 OVENS
Page
BURNER/DRIVE END
IMPINGER X2 OVENS
Page
CONVEYOR, SINGLE
IMPINGER X2 OVENS
Page
CONVEYOR, DUAL BELT
IMPINGER X2 OVENS