Lincoln 3270-2 Jumper, Remove control box cover, Set program jumper on conveyor control to “OFF”

Models: 3240-2 3262 3270-2

1 40
Download 40 pages 14.33 Kb
Page 24
Image 24
Jumper

CONVEYOR CONTROL – PROGRAMMING – DAYTON MOTOR, DIRECT DRIVE

Jumper

“DART” Conveyor control with “UP”, “DOWN” and “ENTER” keys (NEW STYLE).

1.Remove control box cover.

2.Remove top cover from conveyor control. Locate program jumper on conveyor control and set jumper to the “ON” position.

3.Turn oven on, turn conveyor on. Press and hold the “ENTER” key until the Parameter Selection Mode is entered (display will indicate “P 0”).

4.Using the “UP” or “DOWN” keys, select the parameters to be changed (See chart below). When the parameter is selected, press “ENTER”. Use the “UP” or “DOWN” keys to set the desired parameter. Press “ENTER” to save the changes.

5.After all parameters are programmed, select parameter 0 and press the “ENTER” key to return to the running mode.

6.Set program jumper on conveyor control to “OFF”.

7.Reassemble in reverse order and check system operation.

Parameter

40” Oven

62” Oven

70” Oven

Explanation

10

2

2

2

Time Mode Setting (MM:SS)

20

135

135

135

Display minimum setting (value is in seconds)

21

960

960

960

Display maximum setting (value is in seconds)

30

135

135

135

Display setting at reference RPM, parameter 31

31

1609

2494

2816

RPM at which display reference, should be displayed

32

1

1

1

Pulses per revolution of shaft encoder or pickup

50

7

7

7

Activate alarm when pickup stalled

53

1

1

1

Alarm flash enabled

98

5

5

5

Save parameter settings to user default area