CONVEYOR DISASSEMBLY FOR CLEANING

DISASSEMBLY: The Connecting Links may be removed with a pair of pliers by slipping the eye of the connecting link over the wire of the other links. Also notice the direction of the opening on the other links. The belt will have to be reinstalled with the opening facing the same way.

REASSEMBLY: Put conveyor belt back on by setting the rolled belt to the idler end of the conveyor and thread approximately 2/3 of the belt over the bottom slider bed. Be sure belt is not upside down. Reconnect conveyor belt by slipping the connecting links back in place.

NOTE: The Conveyor Belt of the Impinger II and the Advantage oven does not have a tension adjustment. If the belt would become too lose, a link will have to be removed to tighten. A belt that is too tight will also cause operational problems due to excessive drag. We suggest that you may have a qualified service technician perform this adjustment.

WARNING: Careful consideration should be exercised prior to removing a belt link because a belt that is too tight will impede the smooth operation of the conveyor.

FINGER ASSEMBLY REMOVAL

!CAUTION: OVEN MUST BE COOL

1. Open Door. NOTE: Door may be removed by lifting from hinges.

16

Impinger II – Digital Advantage Ops Manual –Dom & Int’l

Page 16
Image 16
Lincoln Series 1100 manual Conveyor Disassembly for Cleaning, Finger Assembly Removal