UTILITY SPECIFICATIONS REQUIRED – ELECTRIC

 

Model

 

Energy

 

Power

 

Voltage

 

Current

 

 

Phase

 

Hz

 

Recommended

 

Recommended

 

Supply Wire

 

Agency Listings

 

 

 

 

 

 

 

 

 

 

Electrical Specification

 

Circuit Breaker

 

Size 90°C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1130/60

 

Electric

10kW

120/208 VAC

48 Amps

1

 

60 Hz

4 Wires, 2 Pole + N + G

2 Pole, 50 Amp

6 AWG

UL, CSA, NSF

1131/61

 

Electric

10kW

120/240 VAC

42 Amps

1

 

60 Hz

4 Wires, 2 Pole + N + G

2 Pole, 50 Amp

8 AWG

UL, CSA, NSF

1132/62

 

Electric

10kW

120/208 VAC

28 Amps

3

 

60 Hz

5 Wires, 3 Pole + N + G

3 Pole, 30 Amp

10 AWG

UL, CSA, NSF

1133/63

 

Electric

10kW

120/240 VAC

25 Amps

3

 

60 Hz

5 Wires, 3 Pole + N + G

3 Pole, 30 Amp

10 AWG

UL, CSA, NSF

 

1130-080-A

Electric

10kW

120/208 VAC

48 Amps

1

 

60 Hz

4 Wires, 2 Pole + N + G

2 Pole, 50 Amp

6 AWG

UL, CSA, NSF

 

1131/61-080-A

Electric

10kW

120/240 VAC

42 Amps

1

 

60 Hz

4 Wires, 2 Pole + N + G

2 Pole, 50 Amp

8 AWG

UL, CSA, NSF

 

1132/62-080-A

Electric

10kW

120/208 VAC

28 Amps

3

 

60 Hz

5 Wires, 3 Pole + N + G

3 Pole, 30 Amp

10 AWG

UL, CSA, NSF

 

1133-080-A

Electric

10kW

120/240 VAC

25 Amps

3

 

60 Hz

5 Wires, 3 Pole + N + G

3 Pole, 30 Amp

10 AWG

UL, CSA, NSF

1134

 

Electric

10kW

380Y/208 VAC

15 Amps

3

 

50 Hz

5 Wires, 3 Pole + N + G

 

 

5 x 2.5mm2

NSF

1135

 

Electric

10kW

415Y/240 VAC

14 Amps

3

 

50 Hz

5 Wires, 3 Pole + N + G

 

 

5 x 2.5mm2

NSF

1136

 

Electric

10kW

240 VAC

42 Amps

1

 

50 Hz

3 Wires, 1 Pole + N + G

 

 

3 x 10.0mm2

NSF

1151

 

Electric

10kW

200VAC

29 Amps

3

 

60 Hz

4 Wires, 3 Pole + G

 

 

3 x 4.0mm2

NSF

 

*1164-XXX-E

Electric

10kW

400/230 VAC

15 Amps

3

 

50 Hz

5 Wires, 3 Pole + N + G

3 Pole, 32 Amp

5 x 2.5mm2

CE, NSF

 

1130-000-A

Electric

10kW

208 VAC

48 Amps

1

 

60 Hz

3 Wires, 2 Pole + G

2 Pole, 50 Amp

6 AWG

UL, CSA, NSF

 

1131-000-A

Electric

10kW

240 VAC

42 Amps

1

 

60 Hz

3 Wires, 2 Pole + G

2 Pole, 50 Amp

8 AWG

UL, CSA, NSF

 

1132-000-A

Electric

10kW

208 VAC

28 Amps

3

 

60 Hz

4 Wires, 3 Pole + G

3 Pole, 30 Amp

10 AWG

UL, CSA, NSF

 

1133-000-A

Electric

10kW

240 VAC

25 Amps

3

 

60 Hz

4 Wires, 3 Pole + G

3 Pole, 30 Amp

10 AWG

UL, CSA, NSF

 

1130-08H-A

Electric

12kW

208 VAC

63 Amps

1

 

60 Hz

3 Wires, 2 Pole + G

2 Pole, 90 Amp

4 AWG

UL, cUL, NSF

 

1131-08H-A

Electric

12kW

240 VAC

54 Amps

1

 

60 Hz

3 Wires, 2 Pole + G

2 Pole, 50 Amp

6 AWG

UL, cUL, NSF

 

1132-08H-A

Electric

12kW

208 VAC

36 Amps

3

 

60 Hz

4 Wires, 3 Pole + G

3 Pole, 70 Amp

8 AWG

UL, cUL, NSF

 

1133-08H-A

Electric

12kW

240 VAC

31 Amps

3

 

60 Hz

4 Wires, 3 Pole + G

3 Pole, 40 Amp

10 AWG

UL, cUL, NSF

* REF MODEL NUMBER KEY

UTILITY SPECIFICATIONS REQUIRED – GAS

 

Model

 

 

Energy

 

 

Power

 

 

Voltage

 

 

Current

 

 

Phase

 

 

Hz

 

 

Recommended

 

 

Recommended

 

 

Gas

 

 

Agency Listings

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electrical Specification

 

 

Circuit Breaker

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1116

 

 

Nat. Gas

 

40,000 BTU

 

120 VAC

 

7 Amps

1

 

 

60 Hz

 

3 Wires, 1 Pole + N + G

 

1 Pole, 15 Amp

 

40,000 BTU at 7 inches, H2O column**

 

CSA, NSF

1117

 

 

L.P. Gas

 

40,000 BTU

 

120 VAC

 

7 Amps

1

 

 

60 Hz

 

3 Wires, 1 Pole + N + G

 

1 Pole, 15 Amp

 

40,000 BTU at 11 inches, H2O column**

 

CSA, NSF

1154

 

 

Nat. Gas

 

45 MJ

 

240 VAC

 

2 Amps

1

 

 

50 Hz

 

3 Wires, 1 Pole + N + G

 

 

 

 

45 MJ/HR at 1.7 kPa, H2O column**

 

AGA*, NSF

1155

 

 

L.P. Gas

 

45 MJ

 

240 VAC

 

2 Amps

1

 

 

50 Hz

 

3 Wires, 1 Pole + N + G

 

 

 

 

45 MJ/HR at 2.73 kPa, H2O column**

 

AGA*, NSF

1156

 

 

Town

 

45 MJ

 

240 VAC

 

2 Amps

1

 

 

50 Hz

 

3 Wires, 1 Pole + N + G

 

 

 

 

45 MJ/HR at 3.6 kPa, H2O column**

 

AGA*, NSF

1157

 

 

Nat. Gas

 

40,000 BTU

 

220/240 VAC

 

2 Amps

1

 

 

50 Hz

 

3 Wires, 1 Pole + N + G

 

 

 

 

40,000 BTU at 7 inches, H2O column**

 

NSF

1158

 

 

L.P. Gas

 

40,000 BTU

 

220/240 VAC

 

2 Amps

1

 

 

50 Hz

 

3 Wires, 1 Pole + N + G

 

 

 

 

40,000 BTU at 11 inches, H2O column**

 

NSF

 

*1154-XXX-E

 

Nat. Gas

 

12kW

 

230 VAC

 

2 Amps

1

 

 

50 Hz

 

3 Wires, 1 Pole + N + G

 

1 Pole, 16 Amp

 

12 kW/HR at 17.4 mB, H2O column**

 

CE, NSF

 

*1155-XXX-E

 

L.P. Gas

 

12kW

 

230 VAC

 

2 Amps

1

 

 

50 Hz

 

3 Wires, 1 Pole + N + G

 

1 Pole, 16 Amp

 

12 kW/HR at 27.4 mB, H2O column**

 

CE, NSF

 

1116-000-A

 

Nat. Gas

 

40,000 BTU

 

120 VAC

 

7 Amps

1

 

 

60 Hz

 

3 Wires, 1 Pole + N + G

 

1 Pole, 15 Amp

 

40,000 BTU at 7 inches, H2O column**

 

CSA, NSF

 

1117-000-A

 

L.P. Gas

 

40,000 BTU

 

120 VAC

 

7 Amps

1

 

 

60 Hz

 

3 Wires, 1 Pole + N + G

 

1 Pole, 15 Amp

 

40,000 BTU at 11 inches, H2O column**

 

CSA, NSF

 

1116-080-A

 

Nat. Gas

 

40,000 BTU

 

120 VAC

 

7 Amps

1

 

 

60 Hz

 

3 Wires, 1 Pole + N + G

 

1 Pole, 15 Amp

 

40,000 BTU at 7 inches, H2O column**

 

CSA, NSF

 

1117-080-A

 

L.P. Gas

 

40,000 BTU

 

120 VAC

 

7 Amps

1

 

 

60 Hz

 

3 Wires, 1 Pole + N + G

 

1 Pole, 15 Amp

 

40,000 BTU at 11 inches, H2O column**

 

CSA, NSF

GAS PRESSURE CONVERSION CHART

Inches of

KPa

m-Bar

Millimeters of

Water Column

Water Column

 

 

3.5

0.87

8.70

88.9

4.5

1.12

11.2

114.3

7

1.74

17.40

177.8

10

2.48

24.87

254.0

10.5

2.61

26.11

266.7

11

2.73

27.36

279.4

14

3.48

34.81

355.6

14.5

3.61

36.05

368.3

*AGA – Australia Gas Association (See 1154 & 1155 above)

**NOTE: For proper operation, the gas valve requires a nominal inlet pressure of 7 inches of H2O for natural gas and 11 inches of H2O column for L.P. gas. A minimum inlet pressure of 1.0 inch of H2O column above the manifold setting (NAT. manifold 3.5” H2O, L.P. manifold 10” H2O) must be maintained with no pressure drop from the no load to full load condition. The maximum inlet pressure must be maintained at or below ½ PSIG (14.5 inches H2O column). Refer to the chart on the left for pressure conversions.

Electrical Supply for Australia:

Single Phase: 240 VAC, 50 Hz / 20 Amp; one neutral & one earth/ground.

Three Phase: 240/415 VAC / 20 Amp; three active, one neutral & one earth/ground.

All ovens require separate service and dedicated neutral.