OPERATION

B-4

OUTBACK™ 145
¤
CONTROLS AND SETTINGS All welder/generator controls are located on the Output Control Panel.
Gasoline engine controls are mounted on the engine. See Figure B.1 and the figures in engine operation section.
WELDER/GENERATOR CONTROLS
See Figure B.1 for the location of the following features:
1. CURRENT CONTROL DIAL: Adjusts continuous cur-
rent output. The amperages on the dial correspond to
the approximate amperages needed for specific
Lincoln welding electrodes.
2. 20 AMP CIRCUIT BREAKER:Provides overload cur-
rent protection for the 120 Volt and 240 Volt
Receptacles
3. WELD POSITIVE OUTPUT TERMINAL: Pro vides the
connection point for either the electrode holder or the
work cable. (Because the OUTBACK™ 145 is a DC
output machine, either output terminal can be used for
either cable.)
4. WELD NEGATIVE OUTPUT TERMINAL: Provides the
connection point for either the electrode holder or the
work cable. (Because the OUTBACK™145 is a DC
output machine, either output terminal can be used for
either cable.)
5. GROUND STUD: Provides a connection point for
connecting the machine case to earth ground for the
safest grounding procedure.

OUTPUT PANEL CONTROLS

FIGURE B.1
6. 240 VOLT RECEPTACLE: Connection point for sup-
plying 250 volt power to operate one electrical
device.
7. 120 VOLT DUPLEX RECEPTACLES (2):Connection
point for supplying 120 volt power to operate one or
has run for maintenance purposes.
8. HOUR METER: Records the time that the engine has
run for maintenance purposes.