B-7

OPERATION

B-7

120V Receptacle Operation:

 

 

Set the Output Control on the Pro-Cut 25 no higher than the 15 amp position.( Higher settings may cause circuit breaker on the OUTBACK™ 145 to trip.)

Maximum material thickness that can be cut is 1/4".

240V Receptacle Operation:

The Pro-Cut 25 may be used for its full range of con- trol.

Maximum material thickness that can be cut is 3/8".

AUXILIARY POWER OPERATION

WARNING

Be sure that any electrical equipment plugged into the generator AC power receptacles can with- stand a ±10% voltage and a ±5% frequency varia- tion. Some electronic devices cannot be powered by the OUTBACK™ 145 Refer to Table A.2, ELEC-

TRICAL DEVICE USE WITH THE OUTBACK™ 145, in the INSTALLATION section of this manual.

-------------------------------------------------------------

GENERAL INFORMATION

The OUTBACK™ 145 is rated at 4750 Peak watts or 4250 continuous watts. It provides both 120 volt and 240 volt power. You can draw up to 20 amps from either side of the 120 volt duplex receptacle, but not more than 35.4 amps from both sides at once. Up to

17.7amps can be drawn from the single 240 volt receptacle.

Electrical loads in watts are calculated by multiplying the voltage rating of the load by the number of amps it draws. (This information is given on the load device nameplate.) For example, a device rated 120 volts, 2 amps will need 240 watts of power (120 x 2 = 240).

You can use Table B.3, AUXILIARY POWER APPLI- CATIONS, to determine the wattage requirements of the most common types of loads you can power with the OUTBACK™ 145 Be sure to read the notes at the bottom of the table.

TO USE THE OUTBACK 145 AS AN AUXILIARY POWER SUPPLY:

1.Start the gasoline engine. See ENGINE OPERA- TION in this section of the manual.

2.Set the current control dial on the output control panel to “MAX.” See Figure B.1.

3.Plug the load(s) into the appropriate 120 volt or 240 volt power receptacle.

NOTE: During welding, the maximum generator out- put for auxiliary loads is 100 watts.

NOTE: You can supply multiple loads as long as the total load does not exceed 4750 Peak watts or 4750 continuous watts. Be sure to start the largest loads first.

TABLE B.2

ELECTRODE SELECTION GUIDE

 

 

 

CURRENT RANGE (AMPS)

AWS

 

ELECTRODE

 

 

 

CLASSIFICATION

ELECTRODE TYPE

POLARITY

 

 

 

 

 

 

3/32 SIZE

1/8 SIZE

5/32 SIZE

E6010

FLEETWELD® 5P

DC+

50-75

75-135

-

E6011

FLEETWELD® 35

DC+

50-75

70-110

80-125

E6011

FLEETWELD® 180

DC+

50-80

55-110

105-125

E6013

FLEETWELD® 37

DC±

70-95

100-135

-

E7018

EXCALIBUR® 7018

DC+

70-100

90-125

125-145

E7018

JETWELD® LH-73

DC+

65-85

90-125

-

E708-17 & E308L-17

BLUE MAX® 308/308L AC-DC

DC+

50-80

75-110

80-125

ENi-CI

SOFTWELD® 99Ni

DC+

50-80

80-110

-

-

WEARSHIELD® ABR

DC+

-

50-150

-

 

 

 

1/8 AND

 

 

 

SHEET THICKNESS

 

THINNER

1/8 AND THICKER

 

 

 

 

 

 

OUTBACK™ 145

¤

Page 21
Image 21
Lincoln Electric Auxiliary Power Operation, General Information, To USE the Outback 145 AS AN Auxiliary Power Supply