INSTALLATION | ||
|
|
|
CONNECTION OF LINCOLN ELEC- TRIC WIRE FEEDERS
Connection of LN-7 or LN-8 to the Ranger 250
1.Shut the welder off.
2.Connect the
3.Set the "WIRE FEEDER VOLTMETER" switch to either "+" or
4.Set the "MODE" switch to the "CV WIRE " posi- tion.
5.Set the "ARC CONTROL" knob to "0" initially and adjust to suit.
6 Set the "WELD TERMINALS" switch to the "REMOTELY CONTROLLED" position.
7. Set the "IDLE" switch to the "HIGH" position.
Connection of an LN-23P Wire Feeder to the Ranger 250
1.Shut the welder off.
2.Connect the
3.Set the "VOLTMETER" switch to
4.Set the "MODE" switch to "CV WIRE" position.
5.Set the "WELD TERMINALS" switch to
"REMOTELY CONTROLLED".
6.Set the "ARC CONTROL" knob to "0" initially and adjust to suit.
7.Set the "IDLE" switch to the "AUTO" position. When not welding, the Ranger 250 engine will be at the low idle speed. If you are using an
Connection of the LN-25 to the Ranger 250
The
Note: The
1.Shut the welder off.
2.For electrode Positive, connect the electrode cable from the
3.Attach the single lead from the front of the
4.Set the MODE switch to the
5.Set the "WELD TERMINALS" switch to "WELD
TERMINALS ON"
6.Set the "ARC CONTROL" knob to "0" initially and adjust to suit.
7.Set the "IDLE" switch to the "AUTO" position. When not welding, the Ranger 250 engine will be at the low idle speed. If you are using an
8.When the gun trigger is closed, the current sens- ing circuit will cause the Ranger 250 engine to go to the high idle speed, the wire will begin to feed and the welding process started. When welding is stopped, the engine will revert to low idle speed after approximately 12 seconds unless welding is resumed.
Connection of LN-742, Spool Gun, and Cobramatic to Ranger 250
1.Shut the welder off.
2.Connect per instructions on the appropriate con- nection diagram in Section F.
RANGER 250