Lincoln Electric 250 manual Installation

Models: 250

1 52
Download 52 pages 27.79 Kb
Page 9
Image 9

A-1

INSTALLATION

A-1

TECHNICAL SPECIFICATIONS - Ranger 250 ( K1725-2, K1725-4)

INPUT - GASOLINE ENGINE

Make/Model

Description

Horsepower

Operating

Displacement cu. in.(cu. cm)

 

@ 3600 RPM

SPEED

Bore x Stroke in.(mm)

 

 

 

 

Starting System

Capacities

 

 

 

 

 

 

12VDC Battery

 

K1725-2

 

 

 

High

38 (624)

and starter

Fuel: 12gal.(45.4L)

 

 

 

 

Kohler CH20

2 Cylinder

20 HP

3.03x 2.64 (77x67)

 

Oil: 2.0qts.(1.9L)

3700RPM

 

OHV

 

 

Push Button

 

4 Cycle

 

Full Load

 

 

 

Air Cooled

 

 

 

Starter

 

K1725-4

Gasoline

 

3500RPM

 

 

 

Engine

 

Low Idle

39.9 (653)

Group 58 Battery

Fuel: 12gal.(45.4L)

Onan P220

 

 

20.5 HP

3.15x 2.56 (80x65)

(435 cold

 

 

2400RPM

OHV

 

 

 

 

 

crank amps)

Oil: 1.6qts.(1.6L)

 

 

 

 

 

 

 

 

RATED OUTPUT @ 104°F(40C°) - WELDER

Welding Output

Volts at Rated Amps

Duty Cycle Max.

OCV @ 3700 RPM

CC STICK & PIPE DC Output

28 Volts at 250 Amps

100%

 

STICK / PIPE Output Range

40 to 250 Amps

 

 

TIG Output Range

20 to 250 Amps

 

80 Volts

CV WIRE DC Output

28 Volts at 250 Amps

100%

 

CV WIRE DC Output

27 Volts at 275 Amps

60%

 

CV WIRE Output Range

14 to 28 volts

 

 

 

 

 

 

RATED OUTPUT @ 104°F(40C°) - GENERATOR

Auxiliary Power 1

9,000 Watts Peak, 8500 Watts Continuous, 60 Hz

120/240 Volts

PHYSICAL DIMENSIONS

 

HEIGHT

 

WIDTH

 

DEPTH

 

 

WEIGHT

 

30.00** in.

 

21.50 in.

 

42.25 in.

 

 

 

 

762.0 mm

 

546.0 mm

 

1073.0 mm

 

500 lbs. (227kg.)

 

 

 

 

 

 

 

 

 

 

**Top of enclosure, add 6.0” (152mm) for exhaust.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ENGINE COMPONENTS

 

 

 

 

LUBRICATION

 

VALVE LIFTERS

 

FUEL SYSTEM

 

GOVERNOR

 

Full Pressure

Solid-(Onan P220 OHV)

Diaphragm Pulse Pump(Onan OHV)

Mechanical Governor

 

with Full Flow Filter

 

Hydraulic- (Kohler)

Mechanical Fuel Pump (Kohler)

5% Regulation (Kohler)

 

 

 

 

 

 

 

 

Centrifugal Flywheel (Onan OHV)

 

AIR CLEANER

 

ENGINE IDLER

 

MUFFLER

 

ENGINE PROTECTION

 

 

 

 

Low noise Muffler: Top outlet

Shutdown on low oil

 

Dual Element

 

Automatic Idler

can be rotated. Made from

pressure.

 

 

 

 

long life, aluminized steel.

 

 

 

 

 

 

 

 

 

 

 

1.Output rating in watts is equivalent to volt-amperes at unity power factor. Output voltage is within ± 10% at all loads up to rated capacity. When welding, available auxiliary power will be reduced.