A-9

INSTALLATION

A-9

 

 

 

7.Set the "IDLE" switch to the "AUTO" position. When not welding, the RANGER 305G engine will be at the low idle speed. If you are using an LN-25 with an internal contactor, the electrode is not energized until the gun trigger is closed.

8.When the gun trigger is closed, the current sens- ing circuit will cause the RANGER 305G engine to go to the high idle speed, the wire will begin to feed and the welding process started. When weld- ing is stopped, the engine will revert to low idle speed after approximately 12 seconds unless welding is resumed.

CAUTION

If you are using an LN-25 without an internal con- tactor, the electrode will be energized when the RANGER 305G is started.

------------------------------------------------------------------------

Connection of LN-742,K487-25 Spool Gun, and

Cobramatic to RANGER 305G

1.Shut the welder off.

2.Connect per instructions on the appropriate con- nection diagram in Section F.