Lincoln Electric 455 M manual Contact your local Lincoln, Authorized Field Service Facility

Models: 455 M

1 42
Download 42 pages 51.45 Kb
Page 34
Image 34

 

E-4

 

 

TROUBLESHOOTING

 

E-4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

 

 

 

 

 

 

 

 

 

PROBLEMS

 

POSSIBLE AREAS OF

 

RECOMMENDED

 

 

(SYMPTOMS)

 

MISADJUSTMENT(S)

 

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT PROBLEMS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Major physical or electrical damage

1. Contact your local authorized

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

is evident when the sheet metal

 

 

Lincoln Electric Field Service

 

 

 

 

 

 

 

covers are removed.

 

 

facility for technical assistance.

 

 

 

 

 

 

 

Input fuses keep blowing, or input

 

 

1. Make certain that fuses or

 

 

 

 

 

 

 

breaker keeps tripping.

 

 

breakers are properly sized.

 

 

 

 

 

 

 

 

 

 

 

See Installation section of this

 

 

 

 

 

 

 

 

 

 

 

manual for recommended

 

 

 

 

 

 

 

 

 

 

 

fuse and breaker sizes.

 

 

 

 

 

 

 

 

 

 

 

2. Welding procedure is drawing

 

 

 

 

 

 

 

 

 

 

 

too much output current, or

 

 

 

 

 

 

 

 

 

 

 

duty cycle is too high.

 

 

 

 

 

 

 

 

 

 

 

Reduce output current, duty

 

 

 

 

 

 

 

 

 

 

 

cycle, or both.

 

 

 

 

 

 

 

 

 

 

 

 

3. There is internal damage to

 

 

 

 

 

 

 

 

 

 

 

the power source. Contact an

 

 

 

 

 

 

 

 

 

 

 

authorized Lincoln Electric

 

 

 

 

 

 

 

 

 

 

 

Service facility.

 

 

 

 

 

 

 

 

Machine will not power up (no

 

 

1. Make certain that the Power

 

 

 

 

 

 

 

lights, no fan, etc.)

 

 

Switch (SW1) is in the ON

 

 

 

 

 

 

 

 

 

 

 

position.

 

 

 

 

 

 

 

 

 

 

 

 

2. Circuit breaker CB4 (in recon-

 

 

 

 

 

 

 

 

 

 

 

nect area) may have opened.

 

 

If all recommended possible areas

 

 

 

 

 

 

 

 

Reset. Also, check input volt-

 

 

of misadjustments have been

 

 

 

 

 

 

 

 

age selection, below.

 

 

checked and the problem persists,

 

 

 

 

 

 

 

 

3. Input voltage selection made

 

 

contact your local Lincoln

 

 

 

 

 

 

 

 

improperly.

Power down,

 

 

Authorized Field Service Facility.

 

 

 

 

 

 

 

 

check input voltage reconnect

 

 

 

 

 

 

 

 

 

 

 

according to

diagram on

 

 

 

 

 

 

 

 

 

 

 

reconnect cover.

 

 

 

 

 

 

 

Thermal LED is lit.

 

 

1. Fan thermostat has opened.

 

 

 

 

 

 

 

 

 

 

 

Check for proper fan opera-

 

 

 

 

 

 

 

 

 

 

 

tion. (Fan should run whenev-

 

 

 

 

 

 

 

 

 

 

 

er output power is on.) Check

 

 

 

 

 

 

 

 

 

 

 

for material blocking intake or

 

 

 

 

 

 

 

 

 

 

 

exhaust louvers, or for exces-

 

 

 

 

 

 

 

 

 

 

 

sive dirt clogging cooling chan-

 

 

 

 

 

 

 

 

 

 

 

nels in machine.

 

 

 

 

 

 

 

 

 

 

 

2. Secondary rectifier or Choke

 

 

 

 

 

 

 

 

 

 

 

thermostat has opened. After

 

 

 

 

 

 

 

 

 

 

 

machine has cooled, reduce

 

 

 

 

 

 

 

 

 

 

 

load, duty cycle, or both.

 

 

 

 

 

 

 

 

 

 

 

Check for material blocking

 

 

 

 

 

 

 

 

 

 

 

intake or exhaust louvers.

 

 

 

 

 

 

 

 

 

 

 

3. DC Bus PC board thermostat

 

 

 

 

 

 

 

 

 

 

 

has opened check for exces-

 

 

 

 

 

 

 

 

 

 

 

sive load on 40VDC supply.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, con- tact your local authorized Lincoln Electric Field Service Facility for technical assistance.

POWER WAVE 455M (CE)

Page 34
Image 34
Lincoln Electric 455 M manual Contact your local Lincoln, Authorized Field Service Facility