TROUBLESHOOTING

 

E-5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PROBLEMS

 

POSSIBLE AREAS OF

 

 

 

 

RECOMMENDED

 

 

(SYMPTOMS)

 

MISADJUSTMENT(S)

 

 

 

 

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT PROBLEMS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Machine wont weld, cant get any

1. Input voltage is too low or too

 

 

 

 

 

 

output. (CR1 will not pull in.)

 

 

high. Make certain that input

 

 

 

 

 

 

 

 

 

 

 

 

voltage is proper, according to

 

 

 

 

 

 

 

 

 

 

 

 

the Rating Plate located on the

 

 

 

 

 

 

 

 

 

 

 

 

rear of the machine.

 

 

 

 

 

 

 

 

 

 

 

 

 

2. If the Thermal LED is also lit,

 

 

 

 

 

 

 

 

 

 

 

 

see Yellow Thermal LED is Lit

 

 

 

 

 

 

 

 

 

 

 

 

section.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3. Primary current limit has been

 

 

 

 

 

 

 

 

 

 

 

 

exceeded. Possible short in out-

 

 

 

 

 

 

 

 

 

 

 

 

put circuit. Turn machine off.

 

 

 

 

 

 

 

 

 

 

 

 

Remove all loads from the out-

 

 

 

 

 

 

 

 

 

 

 

 

put of the machine. Turn back

 

 

 

 

 

 

 

 

 

 

 

 

on. If condition persists, turn

 

 

 

 

 

 

 

 

 

 

 

 

power off, and contact an autho-

 

 

 

 

 

 

 

 

 

 

 

 

rized

Lincoln

Electric

Field

 

 

 

 

 

 

 

 

 

 

 

 

Service facility.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4. This problem will normally be

 

 

 

 

 

 

 

 

 

 

 

 

accompanied by an error code.

 

 

 

 

 

 

 

 

 

 

 

 

Error codes are displayed as a

 

 

 

If all recommended possible areas

 

 

 

 

 

 

 

 

series of red and green flashes by

 

 

 

 

 

 

 

 

 

 

 

 

 

 

of misadjustments have been

 

 

 

 

 

 

 

 

the

status

light.

See

 

 

 

 

 

 

 

 

 

 

 

 

 

 

checked and the problem persists,

 

 

 

 

 

 

 

 

"Troubleshooting the Power Wave

 

 

 

 

 

 

 

 

 

 

 

 

 

 

contact your local Lincoln

 

 

 

 

 

 

 

 

/ Power Feed System Using the

 

 

 

 

 

 

 

 

 

 

 

Status LED" section of this text.

 

 

 

Authorized Field Service Facility.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Machine often noodle welds(out-

 

 

1.Secondary current limit has been

 

 

 

 

 

 

 

 

put is limited to approximately 100

 

 

exceeded, and the machine has

 

 

 

 

 

 

 

 

amps) when running a particular

 

 

phased back to protect itself.

 

 

 

 

 

 

 

 

procedure, especially a procedure

 

 

2. Adjust procedure or reduce load

 

 

 

 

 

 

 

 

with high WFS.

 

 

to lower current draw from the

 

 

 

 

 

 

 

 

 

 

 

 

machine.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3. A single phase input (loss of L2)

 

 

 

 

 

 

 

 

 

 

 

 

will reduce the secondary cur-

 

 

 

 

 

 

 

 

 

 

 

 

rent limit from 570 Amps to 325

 

 

 

 

 

 

 

 

 

 

 

 

Amps.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, con- tact your local authorized Lincoln Electric Field Service Facility for technical assistance.