Lincoln Electric manual Installation, Technical Specifications Power Wave 455/STT

Models: 455

1 33
Download 33 pages 50.66 Kb
Page 8
Image 8

A-1

INSTALLATION

A-1

 

 

 

TECHNICAL SPECIFICATIONS - POWER WAVE 455/STT

INPUT AT RATED OUTPUT - THREE PHASE ONLY

INPUT VOLTS

OUTPUT CONDITIONS

INPUT

 

 

EXCEPT STT PROCESS

CURRENT

 

208V - 60HZ.

450A@38V. 100%

70

 

230V - 60HZ.

450A@38V. 100%

65

 

460V - 60HZ.

450A@38V. 100%

35

 

575V - 60HZ.

450A@38V. 100%

29

 

200V - 50HZ.

400A@36V. 100%

72

 

220V - 50HZ.

400A@36V. 100%

67

 

440V - 50HZ.

400A@36V. 100%

36

 

550V - 50HZ.

400A@36V. 100%

29

 

 

OUTPUT CONDITIONS

 

 

 

STT PROCESS ALL VOLTAGES

 

 

 

325A@33V. 100%

 

 

 

 

OUTPUT

 

OUTPUT CONDITIONS

INPUT

EXCEPT STT PROCESS

CURRENT

570A@43V. 60%

87

570A@43V. 60%

82

570A@43V. 60%

48

570A@43V. 60%

38

500A@40V. 60%

79

500A@40V. 60%

74

500A@40V. 60%

41

500A@40V. 60%

33

OUTPUT CONDITIONS

STT PROCESS ALL VOLTAGES

325A@33V. 100%

OPEN

CURRENT

 

PULSE

PULSE

PULSE AND

AUXILIARY

CIRCUIT

RANGE

 

FREQUENCY

VOLTAGE

BACKGROUND

POWER

VOLTAGE

 

 

 

RANGE

TIME RANGE

 

 

 

 

 

 

 

 

 

75 VDC

5 - 570

 

0.15 - 1000 Hz

5 - 55 VDC

100 MICRO SEC. -

40 VDC AT

 

 

 

 

 

 

3.3 SEC.

10 AMPS

 

 

 

 

 

 

 

115 VAC AT

 

 

 

 

 

 

 

10 AMPS

 

 

 

 

 

 

 

PROCESS CURRENT RANGES (DC)

 

 

CURRENT

 

 

MIG/MAG

 

 

50-570 Amps

 

 

FCAW

 

 

 

40-570 Amps

 

 

SMAW

 

 

 

30-570 Amps

 

 

Pulse

 

 

 

5-750 Amps

 

 

STT

 

 

 

40-325 Amps

 

 

 

 

 

 

 

 

 

RECOMMENDED INPUT WIRE AND FUSE SIZES

INPUT

OUTPUT AMPS/

INPUT AMPERE

TYPE 75°C

TYPE 75°C

TYPE 75°C

VOLTAGE /

DUTY

RATING ON

COPPER WIRE

GROUND WIRE

(SUPER LAG)

FREQUENCY

CYCLE

NAMEPLATE

IN CONDUIT

IN CONDUIT

OR BREAKER

 

 

 

AWG[IEC] SIZES

AWG[IEC] SIZES

SIZE (AMPS)

 

 

 

(MM2)

(MM2)

 

208/60

450/100%

70

4 (25)

8 (10)

80 AMP

230/60

450/100%

65

4 (25)

8 (10)

70 AMP

460/60

450/100%

35

8 (10)

10 (6)

40 AMP

575/60

450/100%

29

8 (10)

10 (6)

40 AMP

 

 

 

 

 

 

200/50

400/100%

72

4 (25)

8 (10)

80 AMP

220/50

400/100%

67

4 (25)

8 (10)

80 AMP

440/50

400/100%

31

8 (10)

10 (6)

40 AMP

550/50

400/100%

29

8 (10)

10 (6)

40 AMP

 

 

 

 

 

 

PHYSICAL DIMENSIONS

HEIGHT

WIDTH

DEPTH

WEIGHT

26.10 in

19.86 in

32.88 in

250 lbs.

663 mm

505 mm

835 mm

114 kg.

 

 

 

 

TEMPERATURE RANGES

OPERATING TEMPERATURE RANGE

0°C to 40°C

STORAGE TEMPERATURE RANGE

-50°C to 85°C

POWER WAVE 455 STT

Page 8
Image 8
Lincoln Electric manual Installation, Technical Specifications Power Wave 455/STT