Lincoln Electric 500 manual Plus, Operation

Models: 500

1 54
Download 54 pages 2.58 Kb
Page 26
Image 26
PLUS

B-9

 

 

 

 

OPERATION

 

 

B-9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TABLE B.4 VANTAGE 500 CUMMINS SIMULTANEOUS WELDING AND POWER LOADS

 

 

WELD

 

1 PHASE

 

3 PHASE

 

 

 

 

 

 

 

 

 

BOTH 1 AND 3 PHASE

 

 

AMPS

 

WATTS

AMPS

 

WATTS

AMPS

 

WATTS

AMPS

 

 

 

0

 

12,000

50

 

20,000

50

 

------

50

 

 

 

100

PLUS

12,000

50

OR

17,800

43

OR

------

50

 

 

 

200

12,000

50

14,000

34

------

50

 

 

 

250

 

12,000

50

 

12,000

29

 

12,000

------

 

 

 

300

 

10,000

42

 

10,000

24

 

10,000

------

 

 

 

400

 

5,600

23

 

5,600

13

 

5,600

------

 

 

 

500

 

0

0

 

0

0

 

0

0

 

TABLE B.5 VANTAGE 500 CUMMINS Extension Cord Length

Recommendations

Current

Voltag

 

 

 

Maximum Allowable Cord Length in ft. (m) for Conductor Size

 

 

(Amps)

e

Load

14 AWG

12 AWG

10 AWG

8 AWG

6 AWG

4 AWG

 

(Volts)

(Watts)

 

 

 

 

 

 

 

 

 

 

 

 

15

120

1800

30

(9)

40

(12)

75

(23)

125

(38)

175

(53)

300

(91)

15

240

3600

60

(18)

75

(23)

150

(46)

225

(69)

350

(107)

600

(183)

20

120

2400

 

 

30

(9)

50

(15)

88

(27)

138

(42)

225

(69)

20

240

4800

 

 

60

(18)

100

(30)

175

(53)

275

(84)

450

(137)

25

240

6000

 

 

 

 

90

(27)

150

(46)

225

(69)

250

(76)

30

240

7200

 

 

 

 

75

(23)

120

(37)

175

(53)

300

(91)

38

240

9000

 

 

 

 

 

 

100

(30)

150

(46)

250

(76)

50

240

12000

 

 

 

 

 

 

 

 

125

(38)

200

(61)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Conductor size is based on maximum 2.0% voltage drop.