| OPERATION |
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| TABLE B.4 VANTAGE 500 CUMMINS SIMULTANEOUS WELDING AND POWER LOADS | ||||||||||
|
| WELD |
| 1 PHASE |
| 3 PHASE |
|
|
|
| |||
|
|
|
|
| BOTH 1 AND 3 PHASE | ||||||||
|
| AMPS |
| WATTS | AMPS |
| WATTS | AMPS |
| WATTS | AMPS |
| |
|
| 0 |
| 12,000 | 50 |
| 20,000 | 50 |
| 50 |
| ||
|
| 100 | PLUS | 12,000 | 50 | OR | 17,800 | 43 | OR | 50 |
| ||
|
| 200 | 12,000 | 50 | 14,000 | 34 | 50 |
| |||||
|
| 250 |
| 12,000 | 50 |
| 12,000 | 29 |
| 12,000 |
| ||
|
| 300 |
| 10,000 | 42 |
| 10,000 | 24 |
| 10,000 |
| ||
|
| 400 |
| 5,600 | 23 |
| 5,600 | 13 |
| 5,600 |
| ||
|
| 500 |
| 0 | 0 |
| 0 | 0 |
| 0 | 0 |
|
TABLE B.5 VANTAGE 500 CUMMINS Extension Cord Length
Recommendations
Current | Voltag |
|
|
| Maximum Allowable Cord Length in ft. (m) for Conductor Size |
|
| |||||||
(Amps) | e | Load | 14 AWG | 12 AWG | 10 AWG | 8 AWG | 6 AWG | 4 AWG | ||||||
| (Volts) | (Watts) |
|
|
|
|
|
|
|
|
|
|
|
|
15 | 120 | 1800 | 30 | (9) | 40 | (12) | 75 | (23) | 125 | (38) | 175 | (53) | 300 | (91) |
15 | 240 | 3600 | 60 | (18) | 75 | (23) | 150 | (46) | 225 | (69) | 350 | (107) | 600 | (183) |
20 | 120 | 2400 |
|
| 30 | (9) | 50 | (15) | 88 | (27) | 138 | (42) | 225 | (69) |
20 | 240 | 4800 |
|
| 60 | (18) | 100 | (30) | 175 | (53) | 275 | (84) | 450 | (137) |
25 | 240 | 6000 |
|
|
|
| 90 | (27) | 150 | (46) | 225 | (69) | 250 | (76) |
30 | 240 | 7200 |
|
|
|
| 75 | (23) | 120 | (37) | 175 | (53) | 300 | (91) |
38 | 240 | 9000 |
|
|
|
|
|
| 100 | (30) | 150 | (46) | 250 | (76) |
50 | 240 | 12000 |
|
|
|
|
|
|
|
| 125 | (38) | 200 | (61) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Conductor size is based on maximum 2.0% voltage drop.
VANTAGE 500 CUMMINS