Lincoln Electric 500 manual COMMANDER / K867 / LN-8CONNECTION DIAGRAM

Models: 500

1 54
Download 54 pages 2.58 Kb
Page 43
Image 43
COMMANDER / K867 / LN-8 CONNECTION DIAGRAM

COMMANDER / K867 / LN-8 CONNECTION DIAGRAM

WARNING

 

 

Do not operate with panels open.

Keep guards in place.

 

Disconnect NEGATIVE (-) BATTERY LEAD

Keep away from moving parts.

 

before servicing.

Only qualified personnel should install,use

 

Do not touch electrically live parts.

or service this equipment.

 

SPARE

}

 

41

 

82

 

LN-8

81

N.C.

WIRE

42

 

FEEDER

 

 

F-6

Manual backgroundVANTAGE 500 CUMMINS

ELECTRODE

TO WORK

14PIN AMPHENOL

K867 UNIVERSAL

ADAPTER PLUG

31

32

2

4

21 GND

31

32

2

4

21

GND

K196

INPUT CABLE

CONNECTION

Manual backgroundManual background TO WORK

ELECTRODE CABLE

TO WIRE FEED UNIT

CAUTION :

75

76

77

} N.D.

A

B C

DIAGRAMS

ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE

AN INCREASE IN THE THE AC AUXILIARY VOLTAGE. IF THIS VOLTAGE GOES OVER 140 VOLTS, WIRE FEEDER CONTROL CIRCUITS MAY BE

DAMAGED. THE ENGINE GOVERNOR SETTING IS PRE-SET AT THE FACTORY - DO NOT ADJUST ABOVE RPM SPECIFICATIONS LISTED IN

THE ENGINE WELDER OPERATING MANUAL.

N.A. WELDING CABLE MUST BE OF PROPER CAPACITY FOR THE CURRENT AND DUTY CYCLE OF IMMEDIATE AND FUTURE

APPICATIONS. SEE OPERATING MANUAL.

N.B. USE VOLTMETER SWITCH TO SELECT DESIRED ELECTRODE POLARITY. POSITION THE SELECTOR SWITCH TO "WIRE WELDING CV".

N.C. INSULATE EACH UNUSED LEAD INDIVIDUALLY.

N.D. SPLICE LEADS AND INSULATE.

7-2000