INSTALLATION | ||
|
|
|
CONNECTION OF THE LN-25 TO THE VANTAGE 500 CUMMINS
The
NOTE: The
•Shut the welder off.
•For electrode Positive, connect the electrode cable from the
•Attach the single lead from the front of the
•Set the SELECTOR switch to the
•Set the “WELDING TERMINALS” switch to “WELD
TERMINALS ON”
•Adjust the “ARC CONTROL” knob to desired crisp- ness. Generally, welding is best if the “ARC CON- TROL” is set to SOFT for MIG and CRISP for INNERSHIELD. You may however, want to start in the middle and adjust (as needed) from there.
•Set the “IDLE” switch to the “AUTO” position. When not welding, the VANTAGE 500 CUMMINS engine will be at the low idle speed. If you are using an LN- 25 with an internal contactor, the electrode is not energized until the gun trigger is closed.
CAUTION
If you are using an
•When the gun trigger is closed, the current sensing circuit will cause the wire to begin to feed and the welding process is started.
CONNECTION OF AN
For connection diagrams and instructions for connect- ing an
•Set the Wire Feeder voltmeter to the proper polarity of the electrode.
CONNECTION OF MAGNUM SC SPOOL GUN TO THE VANTAGE 500 CUMMINS (SEE SECTION F)
CONNECTION OF PRINCE XL SPOOL GUN TO THE VANTAGE 500 CUMMINS
Connection of the Prince XL Spool Gun requires the use of the
•Shut the Welder off.
•For electrode Positive, connect the electrode cable to the "+" terminal of the welder and work cable to the
•Connect the Control Cable of the Spool Gun to the Adapter Module and connect the Control Cable of the Adapter Module to the Welder.
•Connect the Gas Hose.
•Set the MODE switch to the
•Set the "WELD TERMINALS" switch to "WELD
TERMINALS ON".
•Set the "ARC CONTROL" knob to "0" initially and adjust to suit.
•Set the "IDLE" switch to the "High" position
VANTAGE 500 CUMMINS