Lincoln Electric IM10020 Installation, Technical Specifications -TOMAHAWK, Current, Range Voltage

Models: IM10020

1 32
Download 32 pages 9.13 Kb
Page 8
Image 8

 

A-1

 

 

INSTALLATION

A-1

 

TECHNICAL SPECIFICATIONS -TOMAHAWK™ 625

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT - SINGLE PHASE 50 / 60 HERTZ

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Standard Voltage

 

 

 

 

208V, 230V ±10% / 1 / 50 / 60Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATED OUTPUT AT 40° C

 

 

 

Duty Cycle

 

 

CURRENT AMPS

 

VOLTAGE VOLTS

 

 

100%

 

 

24 A

 

89.6VDC

 

 

60%

 

 

29 A

 

91.8VDC

 

35%

 

 

40 A

 

96.0VDC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT

 

 

 

 

 

Current

 

 

Open Circuit

 

Pilot Current

 

Range

 

 

Voltage

 

 

 

 

10-40 Amps

 

 

460 VDC

 

12 Amps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REQUIRED GAS FLOW RATE

70 PSI @ 125-200 SCFH

( 5 Bar. @ 80±20 LITERS/MIN.)

REQUIRED GAS INLET PRESSURE

80 to 110 PSI

(6 Bar. to 7.5 Bar.)

RECOMMEND INPUT WIRE AND FUSE SIZES

For all plasma cutting applications

Based on U.S. National Electrical Code

Ambient Temperature 30oC or Less

Output

AC Input

 

 

 

Fuse

Type S, SO, ST, STO or extra

 

 

Input Cord Plug Size

 

 

Voltage

 

 

 

(Super Lag)

hard usage input cord

 

 

at

 

 

 

Circuit Breaker

AWG (IEC) Sizes

 

 

50/60

 

 

 

(Delay Type)

 

 

 

 

Hertz

 

 

 

 

2 Input Supply Wires 1 Ground Wire

 

 

 

 

 

 

 

 

 

 

230V-1Ø

 

 

 

30 AMPS

 

 

)

40 A

 

6-50P

 

2

2

208V-1Ø

 

 

#12 (3.3 mm )

#12 (3.3 mm

 

 

 

 

 

 

 

 

 

PHYSICAL DIMENSIONS

Height

15.2in. 385 mm

Width

8.5in.

215 mm

Depth

18.9in. 480 mm

Weight

Including

Torch Cable

34.0lbs.

15.4kg.

TEMPERATURE RANGES

OPERATING TEMPERATURE RANGE

-10°C to +40°C

STORAGE TEMPERATURE RANGE

-10°C to +40°C

TOMAHAWK™ 625

Page 8
Image 8
Lincoln Electric IM10020 manual Installation, Technical Specifications -TOMAHAWK, Current, Range Voltage