Lincoln Electric IM10043-A manual General Description, For Auxiliary Power, Engine Operation

Models: IM10043-A

1 53
Download 53 pages 45.8 Kb
Page 20
Image 20
OPERATION

b-1

OPERATION

b-1

 

 

 

SAFETY PRECAUTIONS

Read and understand this entire section before operating your RANGER® 305LPG.

Do not attempt to use this equipment until you have thoroughly read all operating and mainte- nance manuals supplied with your machine. They include important safety precautions, detailed engine starting, operating and maintenance instructions and parts lists.

ELECTRIC SHOCK can kill.

•Do not touch electrically live parts such as output terminals or internal wiring.

•Insulate yourself from the work and ground.

•Always wear dry insulating gloves.

------------------------------------------------------------------------

ENGINE EXHAUST can kill.

•Use in open, well ventilated areas or vent exhaust outside
•Do not stack anything near the engine.

------------------------------------------------------------------------

MOVING PARTS can injure.

•Do not operate with doors open or guards off.

•Stop engine before servicing.

•Keep away from moving parts

------------------------------------------------------------------------

Only qualified personnel should operate this equipment.

ADDITIONAL SAFETY PRECAUTIONS

Always operate the welder with the hinged door closed and the side panels in place as these pro- vide maximum protection from moving parts and insure proper cooling air flow.

GENERAL DESCRIPTION

The RANGER® 305LPG is a gasoline engine pow- ered DC multi-process welding power source and 120

/240 volt AC power generator. The engine drives a generator that supplies three phase power for the DC welding circuit and single phase power for the AC

auxiliary outlets. The DC welding control system uses

state of the art Chopper Technology •Insulate yourself from the work and ground. for superior welding performance. The RANGER 305LPG is NOT RECOMMENED for pipe thawing.

FOR AUXILIARY POWER:

Start the engine and set the IDLER control switch to the desired operating mode. Full power is available regardless of the welding control settings providing no welding current is being drawn.

The auxiliary power of the RANGER® 305LPG con- sists of two 20 Amp-120 VAC GFCI (5-20R) duplex receptacles and one 50 Amp 120/240 VAC (14-50R) receptacle. The 240 VAC receptacle can be split for single phase 120 VAC operation.

ENGINE OPERATION

Before Starting the Engine:

Be sure the machine is on a level surface.

Open top engine door and remove the engine oil dipstick and wipe it with a clean cloth. Reinsert the dipstick and check the level on the dipstick.

Add oil (if necessary) to bring the level up to the full mark. Do not overfill. Close engine door.

See Engine Owner’s Manual for specific oil recom- mendations.

ENGINE EXHAUST can kill.WARNING

The combustion of LPG fuel does produce carbon monoxide. Although the level of CO2 emis- sion is lower than gasoline com- bustion, the exhaust from the Ranger® 305LPG can kill.

Avoid breathing of vapor.

Keep sparks and flame away from tank.

RANGER® 305LPG

Page 20
Image 20
Lincoln Electric IM10043-A manual General Description, For Auxiliary Power, Engine Operation, Safety Precautions