OPERATION

B-5

 

 

 

23. 415 VAC RECEPTACLE

This is a 415VAC receptacle that provides auxil- iary power. This receptacle has 32 amp rating and IP66 rated . Refer to the AUXILIARY POWER RECEPTACLES section in the installa- tion chapter for further information about these receptacles . Also refer to the AUXILIARY POWER OPERATION section later in this chap- ter.

24. GROUND STUD:

Provides a connection point for connecting the machine case to earth ground . Refer to “MACHINE GROUNDING” in the Installation chapter for proper machine grounding informa- tion.

25. RCD:

“Residual Current Device” provides protection from active to ground contact.

RCD will not protect against electrical shock resulting from contact with active and neutral wires.

26. VRD INDICATOR LIGHTS:

Indicates OCV voltage across the output termi- nals. Also indicates operation of VRD in CC mode. A Green light indicates OCV below 30V and a red light indicates OCV above 30V.

During welding both lights will flash, depending on the type of Consumable being used.

BATTERY JUMP START TERMINAL (27-28)

27.POSITIVE BATTERY JUMP START TERMINAL.

28.NEGATIVE BATTERY JUMP START TERMINAL.

12V battery jump start feature is standard . Covered output studs for convenient access, and protection against accidental impact. can be used to jump-start a utility truck with up to 800 cold cranking amps. Can also be used to jump-start the VANTAGE® 575 CUMMINS.

29. BATTERY DISCONNECT SWITCH

Battery disconnect switch provides lockout/tagout capability. Switch is conveniently located on the front bottom of the machine.

30. AIR CLEANER SERVICE INDICATOR

Air cleaner service indicator provides a Go/No-Go visual indication of useful filter service life. Also located inside the engine compartment. (SEE FIG- URE B.2)

FIGURE B.2

30

VANTAGE® 575 CUMMINS