OPERATION | ||
|
|
|
WELDING PARAMETERS
The following parameters are adjustable on the Invertec®
|
| Table B.3 |
|
|
| |
|
|
|
|
|
|
|
| Parameter | Parameter Name |
| Parameter Range | ||
| Symbol |
|
|
|
|
|
|
|
| unit | Min | Max | |
|
|
|
|
|
|
|
|
|
| Sec | 0 | 5 | |
|
|
|
|
|
|
|
|
| Start Current |
| Amps | Min. | Peak |
|
|
|
|
|
|
|
|
| Finish Current |
| Amps | Min | Peak |
|
|
|
|
|
|
|
|
| Min. Current |
| Amps | Min | Peak |
|
|
|
|
|
|
|
|
| Upslope |
| Sec | 0 | 10 |
|
|
|
|
|
|
|
|
| Downslope |
| Sec | 0 | 10 |
|
|
|
|
|
|
|
|
| Spot Time |
| Sec | Off | 10 |
|
|
|
|
|
|
|
|
| Max. Current |
| Amps | 5 | 310 |
|
|
|
|
|
|
|
|
| Pulse Frequency |
| Hz | 0.20 | 2500 |
|
|
|
|
|
|
|
|
| Background Current |
| %Amps | 5% | 95% |
|
|
|
|
|
|
|
|
| % Peak Time |
| % | 5 | 95 |
|
|
|
|
|
|
|
|
| Postflow |
| Sec | 0 | 60 |
|
|
|
|
|
|
|
|
| AC Frequency |
| Hz | 20 | 200 |
|
|
|
|
|
|
|
|
| AC Balance |
| % EN | 35 | 85 |
|
|
|
|
|
|
|
|
| Hot Start |
| % | 0 | 500 |
|
|
|
|
|
|
|
|
| Arc Force |
| % | 0 | 500 |
|
|
|
|
|
|
|